BANGOR, ME —
OSHA Inspection: AUTOMATIC DISTRIBUTORS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AUTOMATIC DISTRIBUTORS in 22 TARGET CIRCLE, BANGOR, ME 04401 (NAICS 441310). OSHA activity number 338914021.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUTOMATIC DISTRIBUTORS
- Site address
- 22 TARGET CIRCLE
- City
- BANGOR
- State
- ME
- ZIP
- 04401
- Mailing
- 22 TARGET CIRCLE, BANGOR, ME 04401
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441310
- Employees
- 35
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.23 C01
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $2,380 · Current $1,547 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder: "D" Area Upper Platform - Employees were exposed to possible falls of 9 feet due to a missing midrail on a seven foot section of the loading platform.
Recent events (2)
- — I (S) $1547
- — Z (S) $2380
1910.26 C02 IV
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $3,570 · Current $2,321 Reduced
General-duty citation text
29 CFR 1910.26(c)(2)(iv): Ladders must be maintained in good usable condition at all times: Warehouse - Two EGA 10 step rolling ladders had defective securing pins located on the upper sections of the ladders.
Recent events (2)
- — I (S) $2320.5
- — Z (S) $3570
1910.36 H02
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $1,785 · Current $1,160 Reduced
General-duty citation text
29 CFR 1910.36(h)(2): The outdoor exit route must be covered if snow or ice is likely to accumulate along the route, unless the employer can demonstrate that any snow or ice accumulation will be removed before it presents a slipping hazard: Emergency exit doors 10 and 11 - The exit route to the designated emergency meeting area was covered with snow.
Recent events (2)
- — I (O) $1160.25
- — Z (S) $1785
1910.132 D01
- Issued
- Mar 6, 2013
- Abate by
- Mar 18, 2013
- Penalty
- Initial $1,785 · Current $1,160 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall: Establishment - The employer did not have a workplace hazard assessment in evaluating hazards present that may necessitate the use of personal protective equipment.
Recent events (2)
- — I (S) $1160.25
- — Z (S) $1785
1910.176 B
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $2,975 · Current $1,934 Reduced
General-duty citation text
29 CFR 1910.176(b): Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse: Warehouse - Approximately 240 metal storage racks were not permanently secured to the floor with industrial grade bolts.
Recent events (2)
- — I (S) $1933.75
- — Z (S) $2975
1910.178 A05
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $2,975 · Current $1,934 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): If the truck is equipped with front-end attachments other than factory installed attachments, the user shall request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: Warehouse - Fall protection was not provided to employees who were changing fluorescent light bulbs while standing in a wooden crate lifted by a Clark forklift.
Recent events (2)
- — I (S) $1933.75
- — Z (S) $2975
1910.178 M05 I
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $1,785 · Current $1,160 Reduced
General-duty citation text
29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means shall be fully lowered, controls shall be neutralized, power shall be shut off, and brakes set: Warehouse - The operator of the Clark forklift did not apply the parking brake before dismounting the machine.
Recent events (2)
- — I (S) $1160.25
- — Z (S) $1785
1910.178 Q07
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected: Warehouse - The employer did not ensure that the Clark forklift was inspected daily for defects.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 II
- Issued
- Mar 6, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded: Picklist Area - An electrical breaker panel was blocked by a metal storage rack.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Automatic Distributors
View Automatic Distributors's full OSHA safety record →
More inspections in this industry (NAICS 441310)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338914021.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.