Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: GORDON WASTE COMPANY, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of GORDON WASTE COMPANY, INC. in FRONT AND BRIDGE STREETS, COLUMBIA, PA 17512 (NAICS 423930). OSHA activity number 338916612.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gordon Waste Company, INC. — free Get an email when a new federal OSHA severe-injury report for Gordon Waste Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
FRONT AND BRIDGE STREETS
City
COLUMBIA
State
PA
ZIP
17512
Mailing
P.O. BOX 389, COLUMBIA, PA 17512
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
34
Ownership type
A

16 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 2 instances 34 exposed
Issued
Apr 26, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.37(a)(3):  Exit routes were not free and unobstructed:  (a) Hildor Area - The exit route leading from the air compressor area was blocked by equipment, on or about February 21, 2013.  (b) Warehouse - The exit near the southeast corner of the building was blocked by concrete barriers, on or about February 21, 2013.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.157 C01

Serious Gravity 1 1 instance 34 exposed
Issued
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): The employer did not provide portable fire extinguishers and did not mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury:   (a) Hildor Area - Fire extinguishers were blocked and not readily accessible to employees, on or about February 21, 2013.   No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G02

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The employer did not provide the education required in paragraph (g)(1) of this section upon initial employment and at least annually thereafter:  (a)  Gordon Waste Company, Inc. - The employer did not provide fire extinguisher training to each employee upon initial employment and annually thereafter, on or about February 21, 2013.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 26, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced

Hazardous substances D150

29 CFR 1910.106(e)(2)(iii): Areas in which flammable liquids were transferred from one tank or container to another container were not separated from other operations in the building by adequate distance or by construction having adequate fire resistance. Drainage or other means was not provided to control spills:   (a)  Warehouse - The spill containment supporting the two diesel fuel tanks was not protected and the corner of the spill containment was damaged, on or about February 21, 2013.   No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.106 E09 III

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 26, 2013
Penalty
Initial $0 · Current $0

Hazardous substances D150

29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:   (a)  Warehouse Diesel Fuel storage Area - Rags containing diesel fuel were not kept in closed metal containers, on or about February 21, 2013.   No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A04

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 26, 2013
Abate by
May 31, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of the powered industrial truck were performed by the employer without the manufacturer's prior written approval:  (a)  Gordon Waste Company, Inc. - The employer did not obtain written approval from the fork lift manufacturer before the tipping attachment was used on the fork lifts, on or about February 21, 2013.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.178 A05

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 26, 2013
Abate by
May 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(5): The user did not request that the truck be marked to identify the attachment(s) and to show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered when the truck was equipped with front-end attachments other than the factory installed attachments:  (a)  Gordon Waste Company, Inc. - The Komatsu powered industrial trucks were not marked to identify the tipping attachment and to show the approximate weight of the truck and attachment combination at maximum elevation with the load laterally centered, on or about February 21, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L03

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(3): Powered industrial truck operators did not receive initial training in the topics included in paragraphs 29 CFR 1910.178(l)(3)(i) and 1910.178(l)(3)(ii):  (a)  Gordon Waste Company, Inc. - The employer did not provide initial powered industrial truck training to an employee operating forklifts, on or about February 21, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 26, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.215(b)(9): Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, were not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:  (a)  Maintenance Cage - The Central Machinery 6 Inch Bench Grinder was not equipped with a tongue guard on the left side, on or about December 21, 2012.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.253 B04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 26, 2013
Penalty
Initial $2,800 · Current $2,100 Reduced

Hazardous substances 00702150X100

29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, such as oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment:  (a)  Maintenance Cage - The set of oxygen and acetylene cylinders located on a cart were located in the same area as a drum of motor oil, a propane tank, and another set of oxygen and acetylene cylinders that were stored against the wall, on or about February 21, 2013.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.1200 F06

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 26, 2013
Penalty
Initial $2,100 · Current $1,575 Reduced

Hazardous substances D150

29 CFR 1910.1200(f)(6): Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked in accordance with either 29 CFR 1910.1200(f)(6)(i) or 29 CFR 1910.1200(f)(6)(ii):   (a)  Warehouse Area, Southeast Corner - The two diesel tanks were not labeled with the identity of the chemical contained therein, on or about February 21, 2012.   No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.1200 F10

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 26, 2013
Penalty
Initial $0 · Current $0

Hazardous substances D150

29 CFR 1910.1200(f)(10): The employer did not ensure that workplace labels or other forms of warning were legible, in English, and prominently displayed on the container, or readily available in the work area throughout each work shift:  (a)  Warehouse Area, Southeast Corner - The warning sign above the two diesel tanks had faded and was no longer legible, on or about February 21, 2012.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C07 III

Other-than-serious 1 instance 3 exposed
Issued
Apr 26, 2013
Abate by
May 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(7)(iii): The employer did not document the basis for determining that all hazards in a permit space had been eliminated, through a certification that contained the date, the location of the space, and the signature of the person making the determination:  (a)  Gordon Waste Company, Inc. - The employer did not document that all of the hazards were eliminated inside of the Bollegraaf baler through a written certification, on or about February 21, 2013.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.146 G04

Other-than-serious 1 instance 1 exposed
Issued
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.146(g)(4): The employer did not certify that the training required by paragraphs (g)(1) through (g)(3) of this section had been accomplished. The certification must contain each employee's name, the signatures or initials of the trainers, and the dates of training:    (a)  Gordon Waste Company, Inc. - The employer did not certify that permit-required confined space training had been accomplished for an employee entering the Bollegraaf baler, on or about February 21, 2013.    No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 II

Other-than-serious 1 instance 2 exposed
Issued
Apr 26, 2013
Abate by
May 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that the periodic inspections had been performed:   (a)  Gordon Waste Company, Inc. - The employer did not certify that the periodic inspections of the de-energization procedures had been accomplished, on or about February 21, 2013.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C07 IV

Other-than-serious 1 instance 1 exposed
Issued
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer shall certify that employee training has been accomplished and is being kept up to date. The certification shall contain each employee's name and dates of training.  (a)  Gordon Waste Company, Inc. - The employer did not certify that training on the energy control procedures had been accomplished for an employee locking out the Bollegraaf baler, on or about February 21, 2013.    No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338916612.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.