On , OSHA opened a planned safety inspection of COLONIAL WALL SYSTEMS, INC. in 8 GLENRIDGE ROAD, GLENVILLE, NY 12302 (NAICS 238140). OSHA activity number 338918287.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Colonial Wall Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Colonial Wall Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8 GLENRIDGE ROAD
City
GLENVILLE
State
NY
ZIP
12302
Mailing
17 SELOVER ROAD, WHITEHOUSE STATION, NJ 08889
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
10
Ownership type
A

6 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 8 exposed
Issued
May 6, 2013
Abate by
May 14, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    a) On or about February 25, 2013 and at times prior thereto at the worksite; employees were performing EFIS work on a tubular scaffold that had 1-2 missing planks throughout each section.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 G04 IV

Serious Gravity 5 1 instance 8 exposed
Issued
May 6, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface:  On or about February 25, 2013 and at times prior thereto at the work site; employees were working from a scaffold that did not have midrails installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 B02

Serious Gravity 5 1 instance 8 exposed
Issued
May 6, 2013
Abate by
May 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.452(b)(2): Transverse bracing forming an "X" across the width of the scaffold was not installed at the scaffold ends and at least at every third set of posts horizontally (measured from only one end) and every fourth runner vertically. Bracing did not extend diagonally from the inner or outer posts or runners upward to the next outer or inner posts or runners:   On or about February 25, 2013 and at times prior thereto at the work site; employees were working from a scaffold that was missing cross bracing on the entire inside of the scaffolding.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 8 exposed
Issued
May 6, 2013
Abate by
May 14, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:    a) On or about February 25, 2013 and at time prior thereto, at the worksite; employees were climbing crossbracing as a means of access to and from the scaffold platforms on the second level.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 F03

Serious Gravity 5 1 instance 8 exposed
Issued
May 6, 2013
Abate by
May 14, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:       a) On or about February 25, 2013 and at times prior thereto, at the jobsite; the scaffold system was not inspected by someone who would be considered a competent person.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.454 B

Serious Gravity 1 1 instance 8 exposed
Issued
May 6, 2013
Abate by
May 14, 2013
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question:    a) On or about February 25, 2013 and at times prior thereto at the jobsite; employees involved in operating, maintaining, and inspecting the scaffold were not trained by a competent person.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338918287.