Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: DECATUR FOUNDARY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DECATUR FOUNDARY, INC. in 1745 N. ILLINOIS STREET, DECATUR, IL 62521 (NAICS 331511). OSHA activity number 338918352.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Decatur Foundary, INC. for free Get an email when a new federal OSHA severe-injury report for Decatur Foundary, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1745 N. ILLINOIS STREET
City
DECATUR
State
IL
ZIP
62521
Mailing
1745 N. ILLINOIS STREET, DECATUR, IL 62521
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
154
Ownership type
Private (A)

4 citations on file for this inspection.

1910.178 P01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2013
Abate by
May 10, 2013
Penalty
Initial $5,400 · Current $3,850 Reduced
29 CFR 1910.178(p)(1):       Powered industrial trucks were found to be in need of repair, defective, or otherwise unsafe, and was not taken out of service until it was restored to safe operating condition:       Employees working in the Blue Room were exposed to struck-by hazards because the "paint booth forktruck" had faulty brakes and was not removed from service.
Recent events (2)
  • · I (S) $3850
  • · Z (S) $5400

1910.303 B08 I

Other-than-serious 1 instance 2 exposed
Issued
Apr 16, 2013
Abate by
May 10, 2013
Penalty
Initial $4,500 · Current $0 Reduced
29 CFR 1910.303(b)(8)(i):     Electric equipment was not firmly secured to the surface on which it was mounted:    Employees working in the Blue Building were exposed to electrical hazards because an electrical outlet on the south wall was not attached to anything and was resting on a metal beam.
Recent events (2)
  • · I (O) $0
  • · Z (S) $4500

1910.305 B01 II

Serious Gravity 5 3 instances 2 exposed
Issued
Apr 16, 2013
Abate by
May 10, 2013
Penalty
Initial $4,500 · Current $3,150 Reduced
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed:    Employees were exposed to electrical hazards:    a. A breaker switch slot was open in the electrical panel labeled BLUE BLDG PANEL in the Blue Building and a covering had not been installed to prevent accidental contact with live conductors.    b. An electrical outlet next to the BLUE BLDG PANEL powering a heater and a battery charger was missing a knockout.    c. An electrical outlet near the main entrance to the Grinding Room was missing a knockout.
Recent events (2)
  • · I (S) $3150
  • · Z (S) $4500

1910.305 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 16, 2013
Abate by
May 10, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.305(b)(2):      Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:      Employees working in the Blue Building were exposed to accidental contact with live electrical conductors because a 120 volt junction box near the electrical panels was missing the front cover.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338918352.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.