OSHA Inspection: USGS, CALIFORNIA WATER SCIENCE CENTER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of USGS, CALIFORNIA WATER SCIENCE CENTER in DRILL AND RIG DIVISION 160 N. STEPHANIE ST, HENDERSON, NV 89074 (NAICS 924110). OSHA activity number 338919293.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Usgs, California Water Science Center — free Get an email when a new federal OSHA severe-injury report for Usgs, California Water Science Center is published. One employer, no account, unsubscribe in one click.
Site address
DRILL AND RIG DIVISION 160 N. STEPHANIE ST
City
HENDERSON
State
NV
ZIP
89074
Mailing
PLACER HALL 6000 J. STREET, SACRAMENTO, CA 95819
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924110
Employees
12
Ownership type
D

16 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 9 instances 9 exposed
Issued
Mar 21, 2013
Abate by
Apr 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    a) At the Drill and Rig Division the work shop and bench work maintenance area; power tools laying on floor and, sharp hand tools and fabricated materials laying on the floor and walk areas causing slip, trip, and fall hazards.      b) At the Drill and Rig Division storage floor and adjacent to steel racks employees were exposed to pinch and caught between hazards when accessing stored materials; 5 to 50 gallon containers of oil and lubricants, crowded hang racks of rigging hardware, and body harnesses and lanyards.
Recent events (1)
  • — Z (S) $0

1910.22 A02

Serious Gravity 1 9 instances 9 exposed
Issued
Mar 21, 2013
Abate by
Apr 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:    a) At the Drill and Rig Division, floors around anchored heavy equipment e.g. metal pipe saw, drill press, and bench worktable had spilled motor oil puddles and fresh grease spots exposing workers to slip, trip and fall hazards at points of operation.
Recent events (1)
  • — Z (S) $0

1910.37 A03

Serious Gravity 1 1 instance 9 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    a) At the Drill and Rig Division west side of facility the exit discharge (door) route was blocked by a two foot by two foot empty box, two commercial heaters on a pallet, wheeled wet vacuum cleaner, and a steel storage rack on metal wheels.
Recent events (1)
  • — Z (S) $0

1910.132 E

Serious Gravity 5 2 instances 9 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(e): The employer did not ensure that employees were not using defective or damaged personal protective equipment in the workplace.    a) At the Drill and Rig Divison work shop, hanging off the top of an anchored "Victor" manufactured drill press a clear face shield was gouged and tar smudged obscuring vision.    b) At the Drill and Rig Divison work shop bench table, hanging on the personal equipment rack, was a clear face shield with obscured vison because of gouges and oil and tar smudges.
Recent events (1)
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 4 instances 9 exposed
Issued
Mar 21, 2013
Abate by
Apr 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(1): The employer did not develop a lockout program to protect employees from unexpected energization of equipment.     a) At the Drill and Rig Division, there was no established program to protect employees in the event of an unexpected electrical startup while servicing or maintaining powered industrial trucks or release of stored band saw energy on "Wells" Metal Band Saw, model no. 8W, L8483.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Serious Gravity 1 4 instances 9 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    a) At the USGS Western Drill and Rig Division work shop, one ABC five (5 lb) pound and one ABC two and one half (2 1/2 lb) pound fire extinguishers were sitting on the floor between two portable tool lockers.       b) At the USGS Western Drill and Rig Division workshop, pallet storage rack. Access to one ABC five (5 lb) pound fire extinguisher was blocked by a chair, hand tools in a container and blue bucket sitting on a worktable.        c) At the USGS Western Drill and Rig Division, a (5 lb) pound wall mounted ABC fire extinguisher was blocked from view and inaccessible because of stacked boxes and stored portable heaters on a pallet in front of the fire extinguisher.
Recent events (1)
  • — Z (S) $0

1910.176 A

Serious Gravity 5 4 instances 9 exposed
Issued
Mar 21, 2013
Abate by
Apr 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.176(a): Where mechanical handling equipment was used, sufficient safe clearances were not allowed for aisles, at loading docks, through doorways or wherever turns or passage had to be made:    a) In the work shop and yard there was insufficient space to safely manuever powered industrial trucks ranging in size from 3,900 lb lift capacity to 25,000lb, lift capacity due to crowded and floor stored equipment conditions.
Recent events (1)
  • — Z (S) $0

1910.176 B

Serious Gravity 1 1 instance 9 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:    a) At the Drill and Rig Division middle storage area a broken pallet on the top tier twelve feet above floor level has a nearly broken off slat creating a struck by hazard to personnel working on the shop floor when it breaks off from pallet.
Recent events (1)
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 2 instances 9 exposed
Issued
Mar 21, 2013
Abate by
Mar 29, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1):    a) At the Drill and Rig division, a portable Miller Thunder bolt XL 300/200 amp stick welder sitting on a red hand truck had a plug-in adaptor with insulation that had separated from the conductor exposing covered wires.      b) At the Drill and Rig division work yard, a yellow seventy-five foot extension cord had slag burns that had melted thru the cord jacket.
Recent events (1)
  • — Z (S) $0

1910.303 B07 IV

Serious Gravity 1 1 instance 9 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:      a) At the Drill and Rig division work shop there was a Makita 4 1/2 inch wheel portable grinder, ser no. ON807694, with a loose ground connector on plug-in adapter.
Recent events (1)
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 1 5 instances 9 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced:    a) At the Drill and Rig Division, on the west wall an orange hard service extension cord plugged into a receptacle had been repaired with electrical tape that was bulging and ends hanging from the cord.
Recent events (1)
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 1 1 instance 9 exposed
Issued
Mar 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:    a) At the Drill and Rig Division, a double insulated Milwaukee portable 4 1/2 inch sander with illegible serial number had cord jacket repaired with electrical tape but showed signs that repair was separating from cord jacket ends causing strain to jacket due to twisting electrical tape.
Recent events (1)
  • — Z (S) $0

1910.1200 G01

Serious Gravity 1 20 instances 9 exposed
Issued
Mar 21, 2013
Abate by
Apr 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:     a)  In the Drill and Rig Division warehouse and work shop; there was fifty gallon barrels of motor oils and five gallon containers of gear lubricants on storage pallets for which there was no material safety data sheets available.
Recent events (1)
  • — Z (S) $0

1960.55 A

Serious Gravity 5 5 instances 12 exposed
Issued
Mar 21, 2013
Abate by
Apr 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1960.55(a): The Agency did not provide safety and health training for supervisory employees:    a) At the USGS Western Drill and Rig Division, the supervisor was not trained to recognize and eliminate hazards, management of the Safety and Occupational Health Program, and train and motivate subordinate staff in work shop safety, portable power tools and housekeeping.
Recent events (1)
  • — Z (S) $0

1903.2 A01

Other-than-serious 1 instance 9 exposed
Issued
Mar 21, 2013
Abate by
Apr 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1903.2(a)(1): The employer did not post and keep posted OSHA notices informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards.:      a) At the USGS Western Drill and Rig Division there was no OSHA Poster posted by the employer in a conspicuous place for employees to view and read.
Recent events (1)
  • — Z (O) $0

1904.40 A

Other-than-serious 2 instances 9 exposed
Issued
Mar 21, 2013
Abate by
Apr 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.    a) The USGS Western Drill and Rig Division did not provide within four business hours requested Calendar Year 2010 OSHA 300A "Summary of Work Related Injuries and Illnesses".
Recent events (1)
  • — Z (O) $0

View Usgs, California Water Science Center's full OSHA safety record →