BELVIDERE, IL —
OSHA Inspection: ACME GRINDING & MANUFACTURING INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ACME GRINDING & MANUFACTURING INC in 6871 BELFORD INDUSTRIAL DR., BELVIDERE, IL 61008 (NAICS 333512). OSHA activity number 338920150.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACME GRINDING & MANUFACTURING INC
- Site address
- 6871 BELFORD INDUSTRIAL DR.
- City
- BELVIDERE
- State
- IL
- ZIP
- 61008
- Mailing
- 6871 BELFORD INDUSTRIAL DR., BELVIDERE, IL 61008
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333512
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C01
- Issued
- Aug 1, 2013
- Abate by
- Oct 1, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: The employer failed to develop energy control procedures for service, repairs, setups, troubleshooting, cleaning and clearing jams. Control of hazardous energy procedures should include but should not be limited to production equipment such as CNC machines. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.178 L01 II
- Issued
- Aug 1, 2013
- Abate by
- Oct 1, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck: The employer authorized production employees to operate the powered industrial trucks prior to providing training that included a practical training, (demonstration performed by the trainer and practical exercises performed by the trainee) and an evaluation of the operators performance in the workplace. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.151 C
- Issued
- Aug 1, 2013
- Abate by
- Oct 1, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: The employer failed to provide an eye wash station in areas where chemicals such as but not limited to Ultra Flux Silver Brazing Flux is used. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.305 G01 IV
- Issued
- Aug 1, 2013
- Abate by
- Oct 1, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv). The employer failed to install and use equipment in approved conditions for use and location. Extension cords were used in lieu of permanent wiring to feed portable equipment and production machinery. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.1200 F05
- Issued
- Aug 1, 2013
- Abate by
- Oct 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: The employer did not ensure that all chemical containers and chemicals transferred into unmarked containers were properly labeled. Employees were exposed to chemicals such as but not limited to cutting, grinding, brazing, cleaning and finishing chemicals. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).