OMAHA, NE ·
OSHA Inspection: OMAHA STEEL CASTINGS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OMAHA STEEL CASTINGS in 4601 FARNAM STREET, OMAHA, NE 68106 (NAICS 333511). OSHA activity number 338920390.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OMAHA STEEL CASTINGS
- Site address
- 4601 FARNAM STREET
- City
- OMAHA
- State
- NE
- ZIP
- 68106
- Mailing
- 4601 FARNAM STREET, OMAHA, NE 68106
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333511
- Employees
- 141
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.101 B
- Issued
- Apr 26, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $4,950 · Current $3,300 Reduced
General-duty citation text
29CFR 1910.101(b) The utilization of all compressed gases in cylinders, portable tanks, shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6: In the Heat Treating Building Weld Arc Station the employer is failing to ensure that gas cylinders stored/used in were secured to prevent tipping and falling.
Recent events (2)
- · I (O) $3300
- · Z (S) $4950
1910.213 I01
- Issued
- Apr 26, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $4,950 · Current $3,300 Reduced
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: In the Pattern Shop the employer is failing to ensure that all unused portion of the band saw blade were guarded. Crescent vertical band saw # 77417
Recent events (2)
- · I (S) $3300
- · Z (S) $4950
1910.219 C03
- Issued
- Apr 26, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $4,950 · Current $3,300 Reduced
General-duty citation text
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven 7 feet or less from floor or working platform was not enclosed: In the Foundry Molding Department the employer is failing to guard the Refcohol Mixer shaft.
Recent events (2)
- · I (O) $3300
- · Z (S) $4950
1910.303 B02
- Issued
- Apr 26, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $3,960 · Current $4,605
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: In the Cleaning Room behind the press break the employer is failing to ensure that the electrical circuit breakers were of the type SWD for switch use. When being used as the sole means for turning the lights in the shipping/cleaning room on and off.
Recent events (2)
- · I (S) $4605
- · Z (S) $3960
1910.303 F02
- Issued
- Apr 26, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: In the Cleaning Room behind the press break the employer is failing to ensure the identity of each breaker within the breaker panel was clearly marked so that the purpose of the individual breaker or the circuit they serve was evident.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 B02 I
- Issued
- Apr 26, 2013
- Abate by
- May 22, 2013
- Penalty
- Initial $5,940 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings will be provided with covers. In the Cleaning Room behind the press break the employer is failing to ensure that cover plates were being used when the breaker was not in place leaving an opening allowing for access to live electrical parts.
Recent events (2)
- · I (S) $0
- · Z (S) $5940
More inspections in this industry (NAICS 333511)