OSHA Inspection: DELAWARE VALLEY CONTRACTORS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DELAWARE VALLEY CONTRACTORS, INC in 1420 CLARION STREET, READING, PA 19601 (NAICS 484220). OSHA activity number 338921349.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Delaware Valley Contractors, INC — free Get an email when a new federal OSHA severe-injury report for Delaware Valley Contractors, INC is published. One employer, no account, unsubscribe in one click.
Site address
1420 CLARION STREET
City
READING
State
PA
ZIP
19601
Mailing
1420 CLARION STREET SUITE B, READING, PA 19601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484220
Employees
30
Ownership type
A

10 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 11, 2013
Abate by
May 7, 2013
Penalty
Initial $3,600 · Current $2,000 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    (a)  MAINTENANCE SHOP - The employer did not provide a standard railing that included a mid-rail around the maintenance pit in the South bay of the maintenance shop, thereby exposing employees to a fall hazard of approximately five (5) feet, on or about February 26, 2013, and at times prior.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $2000
  • — C (S) $3600
  • — Z (S) $3600

1910.24 B

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 11, 2013
Abate by
Nov 1, 2013
Penalty
Initial $4,500 · Current $1,000 Reduced
29 CFR 1910.24(b):  Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations:    (a)  MAINTENANCE SHOP - Employees regularly accessed the second floor of the maintenance shop office by way of a spiral staircase where no other means of access or egress were provided, thereby exposing employees to possible fire hazards, on or about February 26, 2013, and at times prior.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $1000
  • — C (S) $4500
  • — Z (S) $4500

1910.215 A04

Other-than-serious 1 instance 4 exposed
Issued
Apr 11, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    (a)  MAINTENANCE SHOP - The work rest on the Dewalt DW758 8 inch bench grinder (S/N-200630-4L0270 ) was set at a distance of approximately one quarter inch, thereby exposing employee(s) using the bench grinder to serious injuries, including but not limited to amputations and lacerations, on or about February 26, 2013.    No abatement certification or documentation required.
Recent events (3)
  • — F (O) $0
  • — C (S) $3600
  • — Z (S) $3600

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 11, 2013
Abate by
May 7, 2013
Penalty
Initial $3,600 · Current $2,000 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    (a)  MAINTENANCE SHOP - The employer stored compressed gas cylinders in an outdoor storage cage where six (6) oxygen and seven (7) acetylene cylinders were stored directly next to one another, thereby exposing employees to possible fire hazards, on or about February 26, 2013, and at times prior.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $2000
  • — C (S) $3600
  • — Z (S) $3600

1910.303 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 11, 2013
Penalty
Initial $3,600 · Current $1,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a)  MAINTENANCE SHOP - Employees used a Master Electrician six (6) outlet relocatable power tap to supply power to equipment that it was not designed to energize, including a Black and Decker refrigerator, a Nikko stereo receiver, and six (6) battery chargers, thereby exposing employees to fire hazards, on or about February 26, 2013.    No abatement certification or documentation required.
Recent events (3)
  • — F (S) $1000
  • — C (S) $3600
  • — Z (S) $3600

1910.303 F02

Other-than-serious 1 instance 4 exposed
Issued
Apr 11, 2013
Abate by
May 7, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.303(f)(2):  Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose:    (a)  MAINTENANCE SHOP - Employees reset tripped breakers in the maintenance shop using the breaker panel in the Northwest corner of the shop, where all of the breakers were not legibly identified, thereby exposing employees to possible electrical shock injuries, on or about February 26, 2013, and at times prior.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $0
  • — C (S) $3600
  • — Z (S) $3600

1910.303 G01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 11, 2013
Penalty
Initial $4,500 · Current $2,000 Reduced
29 CFR 1910.303(g)(1)(ii):  The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    (a)  MAINTENANCE SHOP - The employer stored equipment directly in front of the electrical breaker panel and two (2) energy disconnect switches, including jack stands, air jacks, and air greasers, thereby exposing employees to possible fire hazards, on or about February 26, 2013.    No abatement certification or documentation required.
Recent events (3)
  • — F (S) $2000
  • — C (S) $4500
  • — Z (S) $4500

1910.305 A02 IX

Other-than-serious 2 instances 4 exposed
Issued
Apr 11, 2013
Abate by
May 7, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.305(a)(2)(ix):  Lamps for general illumination were not protected from accidental contact or breakage by elevating them at least 7 feet from normal working surface or by a suitable fixture or lamp holder with a guard:    (a)  MAINTENANCE SHOP, PARTS ROOM, GROUND FLOOR - The employer did not protect the lighting that was installed in the parts room at a height ranging from approximately six (6 ) feet five (5) inches to six (6) feet nine (9) inches from the ground, thereby exposing employees to electrical shock injuries, on or about February 26, 2013, and at times prior.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $0
  • — C (S) $3600
  • — Z (S) $3600

1910.305 A02 X

Other-than-serious 1 instance 4 exposed
Issued
Apr 11, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.305(a)(2)(x):  Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:    (a)  MAINTENANCE SHOP - Employee(s) used 110 volt electronic equipment, including a stereo receiver and a battery charger, by running an extension cord through a hole in the back of a Snap-on tool chest, where the hole contained a sharp and unprotected metal edge, thereby exposing employees to possible electrical shock injuries, on or about February 26, 2013, and at times prior.    No abatement certification or documentation required.
Recent events (3)
  • — F (O) $0
  • — C (S) $3600
  • — Z (S) $3600

1910.305 G02 III

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 11, 2013
Penalty
Initial $3,600 · Current $1,000 Reduced
29 CFR 1910.305(g)(2)(iii):  Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:        (a)  MAINTENANCE SHOP - Employee(s) used a Master Electrician relocatable power tap that had the insulation pulled back from the plastic housing, exposing the 110 volt conductors, on or about February 26, 2013, and at times prior.    No abatement certification or documentation required.