Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: GREDE HOLDINGS LLC - OMAHA DIVISION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of GREDE HOLDINGS LLC - OMAHA DIVISION in 2614 MARTHA ST, OMAHA, NE 68105 (NAICS 331511). OSHA activity number 338922602.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Grede Holdings LLC - Omaha Division — free Get an email when a new federal OSHA severe-injury report for Grede Holdings LLC - Omaha Division is published. One employer, no account, unsubscribe in one click.
Site address
2614 MARTHA ST
City
OMAHA
State
NE
ZIP
68105
Mailing
2614 MARTHA ST, OMAHA, NE 68105
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
35
Ownership type
A

2 citations on file for this inspection.

1910.95 G06

Serious Gravity 5 51 instances 1 exposed
Issued
Jun 10, 2013
Abate by
Aug 30, 2013
Penalty
Initial $4,250 · Current $2,975 Reduced

Hazardous substances 81108111

29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels.    Audiograms had not been conducted at least annually for each employee required to be in a hearing conservation program. The last facility annual audiometric examination(s) were conducted on December 21, 2011.
Recent events (2)
  • — I (S) $2975
  • — Z (S) $4250

1910.303 G01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 10, 2013
Abate by
Jul 26, 2013
Penalty
Initial $4,250 · Current $2,975 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage.    Working space needed to access a power control panel for the Inductotherm (west) furnace was used for storage of material/equipment including, but not limited to electrical cords, poles, and metal drum(s).
Recent events (2)
  • — I (S) $2975
  • — Z (S) $4250

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338922602.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.