BATON ROUGE, LA ·
OSHA Inspection: CLEAN WATER OPPORTUNITIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of CLEAN WATER OPPORTUNITIES, INC. in 4301 S. JEFFREY DR., BATON ROUGE, LA 70816 (NAICS 325211). OSHA activity number 338922669.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLEAN WATER OPPORTUNITIES, INC.
- Site address
- 4301 S. JEFFREY DR.
- City
- BATON ROUGE
- State
- LA
- ZIP
- 70816
- Mailing
- 4301 S. JEFFREY DR., BATON ROUGE, LA 70816
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 C
- Issued
- Apr 2, 2013
- Abate by
- Apr 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c): Respiratory protection program. This paragraph requires the employer to develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use. The program must be administered by a suitably trained program administrator. In addition, certain program elements may be required for voluntary use to prevent potential hazards associated with the use of the respirator. The Small Entity Compliance Guide contains criteria for the selection of a program administrator and a sample program that meets the requirements of this paragraph. Copies of the Small Entity Compliance Guide will be available on or about April 8, 1998 from the Occupational Safety and Health Administration's Office of Publications, Room N 3101, 200 Constitution Avenue, NW, Washington, DC, 20210 (202-219-4667 On or about February 27, 2013, at the establishment, the employer failed to develop and implement a respiratory protection program for employees wearing tight-fitting respirators during welding operations in the welding shop.
Recent events (1)
- · Z (O) $0
1910.134 F
- Issued
- Apr 2, 2013
- Abate by
- Apr 15, 2013
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.134(f): Fit testing. This paragraph requires that, before an employee may be required to use any respirator with a negative or positive pressure tight-fitting facepiece, the employee must be fit tested with the same make, model, style, and size of respirator that will be used. This paragraph specifies the kinds of fit tests allowed, the procedures for conducting them, and how the results of the fit tests must be used. On or about February 27, 2013, the employer failed to fit test an employee that was observed utilizing a tight-fitting respirator while conducting welding operations at the welding shop.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 325211)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338922669.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.