Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KELLER-MARTIN CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KELLER-MARTIN CONSTRUCTION, INC. in 1406 FITCH, SAN ANTONIO, TX 78211 (NAICS 238990). OSHA activity number 338922776.

Watch Keller-Martin Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Keller-Martin Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1406 FITCH
City
SAN ANTONIO
State
TX
ZIP
78211
Mailing
4930 ENTERPRISE DR, SAN ANTONIO, TX 78249
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.20(b)(2):     The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person (i.e., a person who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has the authority to take prompt corrective measures to eliminate them):    On or about February 25, 2013, inspections were conducted but hazardous conditions found on the second floor with wire rope guardrail system were not corrected.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.502 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(b)(1):   The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:  On or about February 25, 2013, employees were exposed to the hazards of falls of approximately 12 feet to the concrete ground below while accessing the second floor landing, the General Contractor's Superintendent failed to maintain the second floor wire rope guardrail system.  The rope was not tight in that it deflected to approximately 37 inches with minimum force.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0