KANSAS CITY, MO —
OSHA Inspection: BLOUNT INTERNATIONAL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BLOUNT INTERNATIONAL, INC. in 4840 EAST 12TH STREET, KANSAS CITY, MO 64127 (NAICS 333112). OSHA activity number 338923857.
Where did this inspection happen?
- Establishment
- BLOUNT INTERNATIONAL, INC.
- Site address
- 4840 EAST 12TH STREET
- City
- KANSAS CITY
- State
- MO
- ZIP
- 64127
- Mailing
- 4840 EAST 12TH STREET, KANSAS CITY, MO 64127
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333112
- Employees
- 135
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 E01
- Issued
- Penalty
- Initial $4250.00 · Current $2975.00 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: (a) The Mill Platform/Mezzanine did not have an intermediate rail.
Recent events (2)
- — I (S) $2975
- — Z (S) $4250
1910.178 P01
- Issued
- Penalty
- Initial $2550.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) (a) The Yale Forklift # 3 did not have a nonslip surface on the brake pedal and was not taken out of service.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1910.212 A01
- Issued
- Penalty
- Initial $3400.00 · Current $2380.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Maintenance Shop: The Eisen/Bridgeport Mill did not have a guard to cover the unused portion of the bit and chuck above the material being worked. (b) Maintenance Shop: The Progress Drill Press did not have a guard to cover the unused portion of the bit and chuck above the material being worked. (c) Maintenance Shop: The Powermatic Drill Press did not have a guard to cover the unused portion of the bit and chuck above the material being worked. (d) Maintenance Shop: The Dormac 180S lathe did not have a chuck guard.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $2380.00 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Maintenance Shop: The Jet pedestal bench grinder's tongue guards on both side were both adjusted at greater than one fourth inch.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
1910.217 C02 I A
- Issued
- Penalty
- Initial $3400.00 · Current $2380.00 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): (a) Form Department: The AIDA 80 Machine #527, did not prevent entry of hands or fingers into the point of operation as there were three hairpin guards that were missing.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $2380.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) The three Die Carts by the USI Press 523, did not have adequate strain relief as where the electrical wiring was attached the outer insulation was broken exposing interior wiring. (b) Forming Deparment: There was not adequate strain relief for the 2 hand control for the AIDA 2000, Machine # 506, as where the electrical wiring connected to the press the outer insulation was broken exposing interior wiring.
Recent events (2)
- — I (S) $2380
- — Z (S) $3400
More inspections at BLOUNT INTERNATIONAL, INC.
KANSAS CITY, MO—2014-06-05 00:00:00
BLOUNT INTERNATIONAL, INC.
MILWAUKIE, OR—2010-08-05 00:00:00
BLOUNT INTERNATIONAL INC
MILWAUKIE, OR—2009-07-29 00:00:00
BLOUNT INTERNATIONAL INC
View BLOUNT INTERNATIONAL, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333112)
SANDY SPRINGS, GA—2026-04-28 00:00:00
PATTEN SEED COMPANY, LLC
SPRINGFIELD, IL—2026-03-26 00:00:00
GARDEN IRON AND MORE
MARTINS FERRY, OH—2026-03-11 00:00:00
TURF CARE SUPPLY LLC
BRILLION, WI—2026-02-11 00:00:00
ARIENS COMPANY
CLOVIS, CA—2025-12-09 00:00:00
TURF OPERATION FRESNO, INC.
More inspections in MO
CLINTON, MO—2026-07-14 00:00:00
TORCHYLO BUILDERS, LLC.
BLUE SPRINGS, MO—2026-07-13 00:00:00
JORGE MERIDA
KANSAS CITY, MO—2026-07-09 00:00:00
NIAGARA BOTTLING
MONETT, MO—2026-07-09 00:00:00
MONETT METALS INC.
KANSAS CITY, MO—2026-07-08 00:00:00
NGC CONSTRUCTION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338923857.