Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: FRIEDLANDER M&R SUPPLY CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FRIEDLANDER M&R SUPPLY CO. in 550 TRINITY AVENUE, BRONX, NY 10455 (NAICS 444190). OSHA activity number 338924798.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Friedlander M&R Supply CO. for free Get an email when a new federal OSHA severe-injury report for Friedlander M&R Supply CO. is published. One employer, no account, unsubscribe in one click.
Site address
550 TRINITY AVENUE
City
BRONX
State
NY
ZIP
10455
Mailing
550 TRINITY AVENUE, BRONX, NY 10455
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
Employees
13
Ownership type
A

10 citations on file for this inspection.

1910.23 D01

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 14, 2013
Abate by
Sep 10, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section:  On or about 2/27/13  Location: 550 Trinity Ave. Bronx, NY 10455  a) A five step concrete stairway in the loading dock area did not have a standard stair railing or standard handrails along the open side   b) A eight step metal stairway leading to the mezzinine in the warehouse area did not have a standard stair railing or handrails along the open side.
Recent events (1)
  • · Z (S) $1600

1910.24 F

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 14, 2013
Abate by
Sep 10, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs:  On or about 2/27/13  Location: 550 Trinty Ave. Bronx, NY 10455   a) Five cement steps in the loading dock area were heavily damaged with varying amounts of the corners, end and face pieces broken off, making the steps non uniform.
Recent events (1)
  • · Z (S) $1200

1910.178 L01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 14, 2013
Abate by
Oct 1, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  On or about 2/27/13  Location: 550 Trinity Avenue, Bronx, NY 10455  a) Employees operating the Yale forklift SN# GLCO40AFNUAE076 were not adequately trained and provided with the required documentation.
Recent events (1)
  • · Z (S) $1200

1910.212 A01

Serious Gravity 10 3 instances 4 exposed
Issued
Aug 14, 2013
Abate by
Oct 1, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by exposed points of operation and unintentional machine activation:  a) The unused section of the blade on the Greenlee horizontal band saw was unguarded.  b) The protective cover on the foot activation device for the Alphil spot welder, model RTAG was missing.  c) The unused section of the die on the Cincinatti Press Break # 9 was not guarded.
Recent events (1)
  • · Z (S) $2800

1910.303 B01

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 14, 2013
Abate by
Sep 10, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:   On or about 2/27/13   Location: 550 Trinity Ave. Bronx, NY 10455    a) The power cord on the edging machine was damaged. The outer insulation was cut/damaged exposing the insulated inner conductors.   b) The on/off switch on the horizontal band saw was missing its faceplate allowing dust and debris to enter the switch.
Recent events (1)
  • · Z (S) $1600

1910.303 B02

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 14, 2013
Penalty
Initial $2,400 · Current $2,400
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   On or about 2/27/13   Location: 550 Trinity Ave. Bronx, NY 10455   a) A metal quad "J" box, listed only to be used attached to a surface as part of the permanent building wiring, was used as a electrical distribution point at the end of a 100 foot orange extension cord.
Recent events (1)
  • · Z (S) $2400

1910.304 G05

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  On or about 2/27/13  Location 550 Trinity Ave. Bronx, NY 10455  a) The 100 foot orange extension cord located by the horizontal band saw was missing its grounding pin at the male plug end.
Recent events (1)
  • · Z (S) $0

1910.334 A02 II

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:   On or about 2/27/13   Location: 550 Trinity Ave. Bronx, NY 10455   a) A damaged 100 foot orange extension cord was not removed from service. The cord had five areas of damage to the outer insulating jacket that were wrapped in black electrical tape.
Recent events (1)
  • · Z (S) $0

1910.303 F

Serious Gravity 1 3 instances 5 exposed
Issued
Aug 14, 2013
Abate by
Sep 10, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.303(f): Each service, feeder and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:   a) The individual breakers in the circuit breaker panel by the horizontal band saw were not labeled or marked to indicate their purpose.   b) Disconnect switches by the compressor area were not labeled to indicate their purpose.   c) Disconnect switches in the loading dock area were not labeled to indicate their purpose.
Recent events (1)
  • · Z (S) $1200

1910.305 B01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 14, 2013
Abate by
Sep 10, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   On or about 2/27/13   Location: 550 Trinity Ave. Bronx, NY 10455   a) Five openings in the circuit breaker panel by the horizontal band saw were open exposing live electrical buses and wiring
Recent events (1)
  • · Z (S) $2000

View Friedlander M&R Supply CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338924798.