MACON, GA —
OSHA Inspection: PANAPRINT, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PANAPRINT, INC. in 7979 NE INDUSTRIAL BLVD., MACON, GA 31216 (NAICS 323111). OSHA activity number 338925431.
Where did this inspection happen?
- Establishment
- PANAPRINT, INC.
- Site address
- 7979 NE INDUSTRIAL BLVD.
- City
- MACON
- State
- GA
- ZIP
- 31216
- Mailing
- 7979 NE INDUSTRIAL BLVD., MACON, GA 31216
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 88
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.106 D03 II
- Issued
- Abate by
- Penalty
- Initial $3570.00 · Current $2142.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii): Storage cabinet(s) for flammable and combustible liquids were not designed or constructed to meet minimal fire resistance as required: On or about February 28, 2013, employees were exposed to fire hazards when approximately 30 gallons of a class 3 flammable liquid (Nova Pressroom Products) were stored in a retrofitted electrical cabinet.
Recent events (2)
- — I (S) $2142
- — Z (S) $3570
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about February 28, 2013, employees were exposed to struck-by hazards when there were deficiencies in the machine specific lockout/tagout procedures: a. There were no machine specific procedures for some equipment such as, but not limited to, the Motivair Corp. chiller located at the entrance to the warehouse area. b. Machine specific procedures did not include a statement of the intended use of the procedure c. Machine specific procedures did not include procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy d. Machine specific procedures did not include specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them e. Machine specific procedures did not include specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1910.303 G01 I A
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1071.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: On or about February 28, 2013, employees were exposed to hazards when the shutoff boxes for the chillers were located behind stored ink cans.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.146 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: On or about February 28, 2013, employees were exposed to hazards when the bag houses did not have signs.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On or about February 28, 2013, employees were exposed to struck-by hazards when the employer had not had the forklift operators re-evaluated every three years.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 323111)
MUSKEGON, MI—2026-07-08
GRAPHICS HOUSE PUBLISHING, INC
WARMINSTER, PA—2026-07-02
INNOTECH LASER
HERMITAGE, PA—2026-07-01
CCL CONTAINER, INC.
GREEN BAY, WI—2026-06-30
CHARTER NEXT GENERATION, INC.
LEHI, UT—2026-06-25
FIVE INC.
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source