NAPOLEON, OH ·
OSHA Inspection: AUTOMATIC FEED CO.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AUTOMATIC FEED CO. in 476 E. RIVERVIEW ROAD, NAPOLEON, OH 43545 (NAICS 333518). OSHA activity number 338925506.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUTOMATIC FEED CO.
- Site address
- 476 E. RIVERVIEW ROAD
- City
- NAPOLEON
- State
- OH
- ZIP
- 43545
- Mailing
- 476 E. RIVERVIEW ROAD, NAPOLEON, OH 43545
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333518
- Employees
- 73
- Ownership type
- Private (A)
Citations
11 citations on file for this inspection.
1910.147 C04 I
- Issued
- Apr 12, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure energy control procedures were utilized on the Marvel 81 Vertical Band Saw. Employees were exposed to amputation hazards while changing out the blade. b.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure energy control procedures were utilized on the Kalamazoo Vertical Band Saw (Model V-2812-F). Employees were exposed to amputation hazards while changing out the blade.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.147 D03
- Issued
- Apr 12, 2013
- Abate by
- May 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH; On or about March 1, 2013, the employer did not assure the Marvel 81 Vertical Band Saw was properly de-energized by using the established procedures. Employees were exposed to amputation hazards while changing the blade.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 D04 I
- Issued
- Apr 12, 2013
- Abate by
- May 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure lockout and tagout devices were affixed to the electrical box for the Kalamazoo Vertical Band Saw (Model V-2812-F). Employees were exposed to amputation hazards while changing out the blade.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Apr 12, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure employees were protected from the unguarded chuck on the Wilton Drill Press (Model #2232AC). Employees were exposed to caught by hazards while drilling metal parts. b.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure employees were protected from the unguarded chuck on the Enco Lathe. Employees were exposed to caught by hazards while working metal parts.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.212 A03 II
- Issued
- Apr 12, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure employees were protected from unguarded press brakes, including but not limited to the Wysong press brake. Employees were exposed to amputation hazards while bending metal parts. b.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure employees were protected from unguarded press brakes, including but not limited to the Verson press brake. Employees were exposed to amputation hazards while bending metal parts.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.332 B01
- Issued
- Apr 12, 2013
- Abate by
- May 29, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure employees were provided with training on protective equipment for the face, hands, and body to protect against electrical hazards while working on or near energized conductors.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.333 A
- Issued
- Apr 12, 2013
- Abate by
- Jul 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized; a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure employees used electrical safety related work practices when accessing the 480V electrical panel of the Wysong press brake to verify zero energy, in that proper PPE was not worn. Employees were exposed to electrical shock and arc flash hazards from the 480V equipment.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.333 B02 III A
- Issued
- Apr 12, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed: a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure employees placed a lock and tag on an electrical cabinet. Employees were exposed to electrical hazards while removing three fuses from the 480V electrical cabinet for the Wysong press brake.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.335 A01 I
- Issued
- Apr 12, 2013
- Abate by
- May 29, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure an employee(s), verifying the absence of electrical energy in a 480V electrical cabinet for the Wysong press brake was provided with and used electrical protective equipment for the hands and body. The employee(s) was exposed to electrical hazards while performing the electrical test.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.335 A01 IV
- Issued
- Apr 12, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(iv): Employees did not wear nonconductive head protection wherever there was a danger of head injury from electric shock or burns due to contact with exposed energized parts; a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure employees wore nonconductive head protection while verifying zero energy in order to remove three fuses in a 480V electrical cabinet for the Wysong press brake, exposing employees to electrical shock and arc flash hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.335 A01 V
- Issued
- Apr 12, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(v): Employees did not wear protective equipment for the eyes or face wherever there was danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion; a.) Automatic Feed Co. located at 476 E. Riverview Rd. Napoleon, OH 43545; On or about March 1, 2013, the employer did not assure employees wore an arc rate face shield while verifying zero energy in order to remove three fuses in a 480V electrical cabinet for the Wysong press brake, exposing employees to electrical shock and arc flash hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Automatic Feed CO.
View Automatic Feed CO.'s full OSHA safety record →
More inspections in this industry (NAICS 333518)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338925506.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.