CHEYENNE, WY ·
OSHA Inspection: ALEMAN SIDING
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ALEMAN SIDING in 5015 A MINUTEMAN DRIVE, CHEYENNE, WY 82005 (NAICS 238170). OSHA activity number 338925795.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALEMAN SIDING
- Site address
- 5015 A MINUTEMAN DRIVE
- City
- CHEYENNE
- State
- WY
- ZIP
- 82005
- Mailing
- 4500 TUCKAWAY COURT, CHEYENNE, WY 82007
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Jul 9, 2013
- Abate by
- Aug 2, 2013
- Penalty
- Initial $1,600 · Current $880 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Aleman Siding at 5015 A Minuteman Drive, Cheyenne, WY 80005: On or about February 28, 2013, the employer did not ensure that employees wore safety glasses when using pneumatic nail guns. Condition exposed employees to the hazard of projectiles to the eyes. Abatement note: Qualified safety glasses need to say Z87.1.
Recent events (2)
- · I (S) $880
- · Z (S) $1600
1926.451 B03
- Issued
- Jul 9, 2013
- Abate by
- Aug 2, 2013
- Penalty
- Initial $2,400 · Current $1,320 Reduced
General-duty citation text
29 CFR 1926.451(b)(3): The front edge of the platform was not 14 inches or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: a) Aleman Siding at 5015 A Minuteman Drive, Cheyenne, WY 80005: On or about February 28, 2013, the employer set up a pump jack scaffold with the front edge of the scaffold platform 21 inches from the face of the building that was being sided, and no guardrails were in place on the front edge. The employees were not wearing personal fall arrest systems. Conditions exposed employees to fall hazards of 14 feet.
Recent events (2)
- · I (S) $1320
- · Z (S) $2400
1926.451 F07
- Issued
- Jul 9, 2013
- Abate by
- Aug 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) Aleman Siding at 5015 A Minuteman Drive, Cheyenne, WY 80005: On or about February 28, 2013, the employer did not ensure that the pump jack scaffold was erected under the supervision and direction of a competent person. Condition exposed employees to fall hazards of 14 feet.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 G01 VII
- Issued
- Jul 9, 2013
- Abate by
- Aug 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) Aleman Siding at 5015 A Minuteman Drive, Cheyenne, WY 80005: On or about February 28, 2013, the employer provided a pump jack scaffold for employee use that included the following deficiencies: 1) A ladder was used as horizontal guardrails, and the top edge of the top rail of the ladder was only 33 inches above the working platform. The top edge height of the top rail was less than 38 inches high as specified in 1926.451(g)(4)(ii); 2) The uprights connecting the ladder (which was used as horizontal guardrails) were not secured to the platform, and the top rail was not capable of supporting a 200 pound load as specified in 1926.451(g)(4)(vii); 3) The lower rail of the ladder, which served as the horizontal midrail, was not secured, and was not capable of supporting 150 pounds as specified in 1926.451(g)(4)(ix); 4) The scaffold had no endrails, as specified in 1926.451(g)(4)(i); The employees were not wearing personal fall arrest systems. Conditions exposed employees to fall hazards of 14 feet.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.404 F06
- Issued
- Jul 9, 2013
- Abate by
- Aug 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Aleman Siding at 5015 A Minuteman Drive, Cheyenne, WY 80005: On or about February 28, 2013, the employer did not ensure that the extension cord used to power an Hitachi double insulated circular saw, model D 7SB2, serial number C921455, was grounded. Condition exposed employees to electrical shock hazards.
Recent events (2)