SAN ANTONIO, TX —
OSHA Inspection: VIP MASONRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VIP MASONRY in 17018 TURIN RIDGE, SAN ANTONIO, TX 78255 (NAICS 238140). OSHA activity number 338927049.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VIP MASONRY
- Site address
- 17018 TURIN RIDGE
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78255
- Mailing
- 5772 GREYROCK DR., SAN ANTONIO, TX 78228
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 26
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.102 A01
- Issued
- Mar 22, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On or about March 01, 2013, employee was exposed to being struck in the eyes and face by fragments, from the bricks being cut with the masonry saw, when not using safety glasses and a face shield.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1926.451 C02
- Issued
- Mar 22, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about March 01, 2013, employees were exposed to falls of up to approximately 9 feet 5 inches in height to the ground level below, while installing brick veneer, to the front wall of the residential home, from a welded frame scaffold which was not provided with base plates or mud sills.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1926.451 C02 II
- Issued
- Mar 22, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects shall not be used to support scaffolds or platform units: On or about March 01, 2013, employees were exposed to falls of approximately 9 feet 5 inches in height, to ground level, while installing the brick veneer to the front of the home, while using a welded frame scaffold which had two of the four scaffold frame legs resting on piles of stones.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Mar 22, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: On or about March 01, 2013, employees were exposed to falls of up to approximately 12 feet 5 inches in height to the ground level below, while using a welded frame scaffold, which was not provided with a ladder, to access the working platform.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.451 G04 I
- Issued
- Mar 22, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: On or about March 01, 2013, employees were exposed to the hazard of falls of up to approximately 12 feet 6 inches in height, to the ground level below, from a welded frame scaffold which was not provided with a guard rail at the end of the scaffold platform, while installing brick veneer to the wall from a welded frame scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.451 H02 II
- Issued
- Mar 22, 2013
- Abate by
- Mar 28, 2013
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: On or about March 01, 2013, employees were exposed to being struck by bricks, while working below a scaffold platform, which was approximately 12 feet 5 inches in height to ground level, and not having a toeboard, while employees were installing the brick veneer to the home.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
More inspections at VIP Masonry
View VIP Masonry's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338927049.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.