Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KAISER & JOHNSON EXPORT PACKAGING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KAISER & JOHNSON EXPORT PACKAGING INC. in 3200 S. KINGSHIGHWAY BLVD, SUITE B, SAINT LOUIS, MO 63139 (NAICS 321920). OSHA activity number 338935943.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kaiser & Johnson Export Packaging INC. — free Get an email when a new federal OSHA severe-injury report for Kaiser & Johnson Export Packaging INC. is published. One employer, no account, unsubscribe in one click.
Site address
3200 S. KINGSHIGHWAY BLVD, SUITE B
City
SAINT LOUIS
State
MO
ZIP
63139
Mailing
3200 S. KINGSHIGHWAY BLVD, SUITE B, SAINT LOUIS, MO 63139
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
12
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 20, 2013
Abate by
May 6, 2013
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a. Where saws, both hard wired and cord/plug, compressor, and hand tools were used in the manufacturing of wood packaging, a lockout/tagout program had not been developed and implemented, including requiring lockout of equipment, such as when changing saw blades, documented training, and documented annual inspection (audit) of the program.    Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $1700

1910.213 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 20, 2013
Abate by
May 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.213(d)(1):     Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    a. The table saw was used without a guard.    Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 C03 I

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 20, 2013
Abate by
May 6, 2013
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1910.303(c)(3)(i):     All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:    a. A hand grinder power cord was spliced with a cord that did not match the original equipment, including non-industrial insulation; the splice was not an approved splice (electrical tape).     Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1910.304 G05

Serious Gravity 1 2 instances 3 exposed
Issued
Mar 20, 2013
Abate by
May 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5):     The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a. Cooling fans were missing ground pins (equipment grounding conductor).    Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 20, 2013
Abate by
May 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii):     There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:    a. Power cord insulation was damaged on cooling fans.    Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Kaiser & Johnson Export Packaging INC.'s full OSHA safety record →