ANNA, TX —
OSHA Inspection: TDR MILLWORK
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TDR MILLWORK in 920 WEST WHITE STREET, ANNA, TX 75409 (NAICS 337110). OSHA activity number 338939143.
Where did this inspection happen?
- Establishment
- TDR MILLWORK
- Site address
- 920 WEST WHITE STREET
- City
- ANNA
- State
- TX
- ZIP
- 75409
- Mailing
- 920 WEST WHITE STREET, ANNA, TX 75409
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 14
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $550.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition: This violation was observed on February 26, 2013, at an establishment located at 920 West White Street, Anna, Texas: on the production areas where employees were exposed to the hazards of fire, deflagration, and explosion from the accumulation of a class II combustible saw dust had accumulated on equipment, walls and ledges at depths of up to (3)inches.
Recent events (2)
- — I (S) $550
- — Z (S) $2800
1910.22 A02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(2): The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition: This violation was observed on February 26, 2013, at an establishment located at 920 West White Street, Anna, Texas: on the production areas where employees were exposed to the hazards of fire, deflagration, and explosion from the accumulation of a class II combustible saw dust on the workroom floors.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 E05
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $300.00 Reduced
General-duty citation text
29 CFR 1910.107(e)(5): Spray containers were not provided with a visible gage. This violation occurred on or before April 18, 2013 at an establishment located at 920 West White Street, Anna, TX 75409; where a spray painting employee operating a Falcon paint delivery system did not have the air pressure gage visible to the operator. Employees were exposed to inhalation, skin contact, and fire hazards as a result of this work practice.
Recent events (2)
- — I (S) $300
- — Z (S) $1600
1910.107 G07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms. This violation occured on or about April 18, 2013 at an establishment located at 920 West White St. Suite 109 Anna, Texas 75409; at the spray painting area where the employer did not display "NO SMOKING" signs.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $300.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer did not establish and implement a written respiratory protection program with worksite-specific procedures: This violation occurred on February 25, 2013 at an establishment located at 920 West White St. Suite 109 Anna, Texas 75409 ; at least one (1) employee was required to wear a negative pressure half mask elastomeric respirator for protection against solvent mists containing toluene compounds and against organic vapors.
Recent events (2)
- — I (S) $300
- — Z (S) $1600
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $400.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: This violation occurred on or before February 26, 2013 at an establishment located at 920 West White Street, Anna, TX; where employees were exposed to electrical hazards: a) In the Line Bore Area; where a piece of of the cover to 110 volt-outlet receptacle was missing. b) In the Custom Wood Work Area; where the cover to a 110 volt duplex electrical outlet was missing.
Recent events (2)
- — I (S) $400
- — Z (S) $2000
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: This violation occurred on or before February 26, 2013, at an establishment located at 920 West White St. Suite 109 Anna, Texas 75409 employees were exposed to an electrical hazard: The protective sleeve to a portable extension cord connected to a Dewalt chop saw had been pulled loose from the plug.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C02 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $550.00 Reduced
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment was not approved for the class of location, and for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was present: This violation occurred on January 26, 2013, at a work place located at 920 West White St. Suite 109 Anna, Texas 75409 ; on the production area where the employer did not ensure that equipment is approved for the class of location, and for the ignitable or combustible properties of the saw dust: a) Employees operated a Dewalt Chop Saw and other power tools in the Custom Wood Work Area which dispensed saw dust (Class II combustible dust). The operation of the Dewalt Chop Saws and other power tools created the release of the saw dust intermittently throughout the day. General purpose wiring, breaker panel boxes, disconnect switches, and receptacles were not dust-tight ignition proof and approved for Class II locations. b)Employees operated a Dewalt Chop Saw and other power tools in the Line Bore Area which dispensed saw dust (Class II combustible dust). The operation of the Dewalt Chop Saws and other power tools created the release of the saw dust intermittently throughout the day. General purpose wiring, breaker panel boxes, disconnect switches, and receptacles were not dust-tight ignition proof and approved for Class II locations. c) Employees operated an Onsurd Router and other automatic tools in Bay 4 which dispensed saw dust (Class II combustible dust). The operation of the Dewalt Chop Saws and other power tools created the release of the saw dust intermittently throughout the day. General purpose wiring, breaker panel boxes, disconnect switches, and receptacles were not dust-tight ignition proof and approved for Class II locations.
Recent events (2)
- — I (S) $550
- — Z (S) $2800
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $300.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: This violation occurred on February 26, 2013 at an establishment located at 920 West White St Anna, TX 75409; where employees used products such as but not limited to SLX Denatured Alcohol, Speedline Lacquer High Build Lacquer Clear Satin , Pro Mar E-Z Sanding Lacquer Sealer.
Recent events (2)
- — I (S) $300
- — Z (S) $1600
More inspections in this industry (NAICS 337110)
VESTAL, NY—2026-07-08
BARNWOOD KITCHEN CABINETS
DEERWOOD, MN—2026-07-02
111522 - DUFFNEY CUSTOM CABINETS LLC
EVERETT, WA—2026-06-29
WA317991850 - JMC CABINETS & INTERIORS INC
PUEBLO, CO—2026-06-26
WESTWIND WOOD SPECIALTIES INC.
BRAINERD, MN—2026-06-25
111484 - TRADITIONAL CABINETRY LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source