Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PSC INDUSTRIAL SERVICES LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of PSC INDUSTRIAL SERVICES LLC in 1520 20TH STREET, GRANITE CITY, IL 62040 (NAICS 561790). OSHA activity number 338941768.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PSC Industrial Services LLC — free Get an email when a new federal OSHA severe-injury report for PSC Industrial Services LLC is published. One employer, no account, unsubscribe in one click.
Site address
1520 20TH STREET
City
GRANITE CITY
State
IL
ZIP
62040
Mailing
P.O. BOX 852, ROBINSON, IL 62454
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
20
Ownership type
A

4 citations on file for this inspection.

1910.147 C06 I B

Deleted Serious Gravity 10 2 instances 6 exposed
Issued
Mar 21, 2013
Abate by
Apr 16, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i)(B):     The periodic inspection of the energy control procedure was not conducted to correct any deviations or inadequacies identified:      The employers periodic inspection did not ensure that employees routinely locked out and verified machinery and/or equipment they were working on or near was isolated from hazardous energy sources.
Recent events (3)
  • — F (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1910.147 D03

Deleted Serious Gravity 10 2 instances 6 exposed
Issued
Mar 21, 2013
Abate by
Mar 27, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.147(d)(3):     All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):      a)	 On or about September 21, 2012, in the BOF (Basic Oxygen Furnace) area, US Steel authorized employees were tasked to perform Lockout/Tagout operations on the C2 conveyor to allow PSC contract employees to perform cleanup duties.  The #2 Secondary Damper was inadvertently deenergized instead of the conveyor, leaving the C2 conveyor energized.      b)	On or about September 25, 2012, in the BOF (Basic Oxygen Furnace) area, US Steel authorized employees were tasked to perform Lockout/Tagout operations on the C3 conveyor to allow PSC contract employees to preform cleanup duties.  The C3 conveyor was properly locked out, but the Tripper Car that straddles the conveyer, where the contractors were working, had deenergized or disabled during the cleanup operations.
Recent events (3)
  • — F (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1910.147 D04 I

Deleted Serious Gravity 10 2 instances 6 exposed
Issued
Mar 21, 2013
Abate by
Mar 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i):     Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    a)	 On or about September 21, 2012, in the BOF (Basic Oxygen Furnace) area, US Steel authorized employees were tasked to perform Lockout/Tagout operations on the C2 conveyor to allow contract employees to perform cleanup duties.  The #2 Secondary Damper was inadvertently deenergized instead of the conveyor, leaving the C2 conveyor without a lockout or tagout device applied.      b)	On or about September 25, 2012, in the BOF (Basic Oxygen Furnace) area, authorized employees were tasked to perform Lockout/Tagout operations on the C3 conveyor to allow PSC contract employees to perform cleanup duties.  The C3 conveyor was properly locked out, but the Tripper Car that straddles the conveyer, where the contractors were working, did not have a lockout or tagout device applied.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 D06

Serious Gravity 10 2 instances 10 exposed
Issued
Mar 21, 2013
Abate by
Mar 27, 2013
Penalty
Initial $2,800 · Current $5,000
29 CFR 1910.147(d)(6):     Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:      a)	 On or about September 21, 2012, in the BOF (Basic Oxygen Furnace) area, US Steel authorized and PSC employees were tasked to perform Lockout/Tagout operations on the C2 conveyor.  The #2 Secondary Damper was inadvertently deenergized instead of the conveyor, leaving the C2 conveyor energized.  Authorized employees did not verify that the C2 Conveyor was isolated and deenergized prior to the start of cleanup duties.      b)	On or about September 25, 2012, in the BOF (Basic Oxygen Furnace) area, US Steel authorized and PSC employees were tasked to perform Lockout/Tagout operations on the C3 conveyor.  The C3 conveyor was properly locked out, but the Tripper Car that straddles the conveyer, where the contractors were working, had not been deenergized and disabled during the cleanup operations.   Authorized employees did not verify that the Tripper Car was isolated and deenergized prior to the start of cleanup duties.
Recent events (3)
  • — F (S) $5000
  • — C (S) $2800
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338941768.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.