Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: SUPERIOR METAL TREATING & EQUIPMENT, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SUPERIOR METAL TREATING & EQUIPMENT, INC. in 2540 INDIANA AVENUE, KANSAS CITY, MO 64127 (NAICS 332811). OSHA activity number 338941842.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Superior Metal Treating & Equipment, INC. for free Get an email when a new federal OSHA severe-injury report for Superior Metal Treating & Equipment, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2540 INDIANA AVENUE
City
KANSAS CITY
State
MO
ZIP
64127
Mailing
2540 INDIANA AVENUE, KANSAS CITY, MO 64127
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332811
Employees
33
Ownership type
A

4 citations on file for this inspection.

1910.178 P01

Serious Gravity 5 2 instances 15 exposed
Issued
Mar 20, 2013
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.178(p)(1):     Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):    (a) Furnace Room:  The TCM propane powered forklift, the short mast forklift, did not have a nonslip surface on the brake pedal and was not taken out of service.    (b) Blade Room:  The TCM FCG25 propane powered forklift did not have a nonslip surface on the brake pedal and was not taken out of service.
Recent events (2)
  • · I (S) $1666
  • · Z (S) $2380

1910.215 B09

Serious Gravity 5 2 instances 9 exposed
Issued
Mar 20, 2013
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.215(b)(9):     The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a) Blade Room:  The Jet Bench grinder tongue guards were adjusted at greater than one fourth inch on both the left and right grinding wheels.
Recent events (2)
  • · I (S) $1666
  • · Z (S) $2380

1910.303 G02 I

Serious Gravity 5 2 instances 12 exposed
Issued
Mar 20, 2013
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    (a)  The Vertical Load/Unload Table in the Temper Room had a rectangular electrical box of more than 50 volts that was not guarded with a cover.    (b)  The Vertical Load/Unload Table by the LIPE Press had an oval electrical box of more than 50 volts that was not guarded with a cover.
Recent events (2)
  • · I (S) $1666
  • · Z (S) $2380

1910.305 A01 I

Serious Gravity 5 2 instances 10 exposed
Issued
Mar 20, 2013
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.305(a)(1)(i):     Metal raceways, cable armor, and other metal enclosures for conductors were not connected to all boxes, fittings, and cabinets to provide effective electrical continuity:    (a) The Vertical Load/Unload Table in the Temper Room did not have effective electrical continuity as the electrical metal conduit was not connected from the control to the junction box on the table.     (b) The Vertical Load/Unload Table in the LIPE Press area did not have effective electrical continuity as the electrical metal conduit was not connected from the control to the oval junction box, and from the oval junction box to the metal conduit beneath it.
Recent events (2)
  • · I (S) $1666
  • · Z (S) $2380

View Superior Metal Treating & Equipment, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338941842.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.