Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: AMSTED RAIL COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMSTED RAIL COMPANY, INC. in 1700 WALNUT ST., GRANITE CITY, IL 62040 (NAICS 336510). OSHA activity number 338943491.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amsted Rail Company, INC. for free Get an email when a new federal OSHA severe-injury report for Amsted Rail Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1700 WALNUT ST.
City
GRANITE CITY
State
IL
ZIP
62040
Mailing
1700 WALNUT ST., GRANITE CITY, IL 62040
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336510
Employees
200
Ownership type
Private (A)

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 200 exposed
Issued
Aug 28, 2013
Abate by
Sep 4, 2013
Penalty
Initial $6,300 · Current $6,300
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish a place of employment, which was free from recognized hazards that was causing or likely to cause death or serious physical harm to employees in that employees were exposed to burn and explosion hazards:      Employees, working in the area of the natural gas heaters, were exposed to burn and explosion hazards in that the HeatStar HS125NG area heaters were provided with natural gas through the use of Grade R Acetylene Only flexible hose and the area heaters were used as permanent area heaters for general industry instead of the manufacturers intended use as a heater for buildings under construction, alteration, or repair.      Among other methods, the following is a feasible and acceptable method to correct this hazard.      NFPA 54 / ANSI Z223.1  2012 Section 9.1.1 which states Appliances, equipment, and accessories shall be approved.  Remove the HeatStar HS125NG area heater from service in the facility.  Discontinue use of incompatible hose to supply fuel-gas.
Recent events (3)
  • · F (S) $6300
  • · C (S) $6300
  • · Z (S) $6300

1910.253 E05 I

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 28, 2013
Abate by
Sep 4, 2013
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.253(e)(5)(i): Hose for oxy-fuel gas service did not comply with the Specification for Rubber Welding Hose, 1958, Compressed Gas Association and Rubber Manufacturers Association:       Employees performing fuel gas and oxygen cutting were exposed to burn and explosion hazards in that the Grade R Acetylene Only hose was not intended for use with the facility natural gas supply and the employer did not ensure the hose for oxygen and fuel gas service complied with the Specification for Rubber Welding Hose, 1958, Compressed Gas Association and Rubber Manufacturers Association.
Recent events (3)
  • · F (S) $0
  • · C (S) $6300
  • · Z (S) $6300

1910.253 A01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Aug 28, 2013
Abate by
Sep 4, 2013
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.253(a)(1): Mixtures of fuel gases and air or oxygen that may be explosive during oxygen-fuel gas welding were not guarded against:     Employees performing fuel gas and oxygen cutting were exposed to burn and explosion hazards and the employer did not ensure mixtures of fuel gas and air or oxygen that may be explosive during oxygen-fuel gas welding were guarded against.
Recent events (3)
  • · F (S) $0
  • · C (S) $6300
  • · Z (S) $6300

1910.253 A04

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 28, 2013
Abate by
Sep 4, 2013
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.253(a)(4): Rules and instructions covering the operations and maintenance of oxygen or fuel-gas supply equipment including generators, and oxygen or fuel-gas distribution piping systems were not readily available:     Employees performing fuel gas and oxygen cutting were exposed to burn and explosion hazards and the employer did not provide rules and instructions covering the operations and maintenance of oxygen or fuel-gas supply equipment.
Recent events (3)
  • · F (S) $6300
  • · C (S) $6300
  • · Z (S) $6300

1910.253 E05 V

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 28, 2013
Abate by
Sep 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.253(e)(5)(v): Hose showing leaks, burns, worn places, or other defects rendering it unfit for service were not repaired or replaced:    Employees performing fuel gas and oxygen cutting were exposed to burn and explosion hazards and the employer did not ensure hoses showing leaks, burns, worn places, or other defects rendering it unfit for service were repaired or replaced.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

View Amsted Rail Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338943491.