OSHA Inspection: U.S. DEPT. OF THE INTERIOR FISH AND WILDLIFE SERVICE OFFICE OF LAW ENFORCEMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPT. OF THE INTERIOR FISH AND WILDLIFE SERVICE OFFICE OF LAW ENFORCEMENT in 370 AMAPOLA AVE # 114, TORRANCE, CA 90501 (NAICS 924120). OSHA activity number 338944176.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept. of the Interior Fish and Wildlife Service Office of LAW Enforcement for free Get an email when a new federal OSHA severe-injury report for U.S. Dept. of the Interior Fish and Wildlife Service Office of LAW Enforcement is published. One employer, no account, unsubscribe in one click.
Site address
370 AMAPOLA AVE # 114
City
TORRANCE
State
CA
ZIP
90501
Mailing
370 AMAPOLA AVE # 114, TORRANCE, CA 90501
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
22
Ownership type
Federal government (D)

11 citations on file for this inspection.

1910.36 G02

Serious Gravity 5 1 instance 18 exposed
Issued
Mar 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.    Live animal room - On or about 3/5/2013, a wooden platform restricted the exit access to less than 28 inches wide.
Recent events (1)
  • · Z (S) $0

1910.37 A03

Serious Gravity 5 1 instance 22 exposed
Issued
Mar 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    On or about 3/5/2013, an emergency exit route was obstructed by a stuffed tiger display.
Recent events (1)
  • · Z (S) $0

1910.37 A04

Serious Gravity 5 1 instance 18 exposed
Issued
Mar 26, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times.    In the Warehouse - On or about 3/5/2013, self-illuminating emergency exit signs above exit doors were not in proper working order.
Recent events (1)
  • · Z (S) $0

1910.176 B

Serious Gravity 5 5 instances 22 exposed
Issued
Mar 26, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b): Storage of material created a hazard:    a) Supply room - On or about 3/5/2013, combustibles (cardboard boxes, papers) were stored near the water heater.    b) Warehouse, Aisle way - On or about 3/5/2013,  a table was stored unsecured from sliding in an aisle way and could present a tripping hazard.    c) Warehouse, adjacent to exit door  - On or about 3/5/2013, folding chairs were stored unsecured so the chairs can slide and present tripping hazards to an exit route.    d) Server room  - On or about 3/5/2013, boxes were stored in an unstable manner.    e) Equipment room  - On or about 3/5/2013, a tripod and shovel were stored unsecured from sliding.
Recent events (1)
  • · Z (S) $0

1910.176 C

Serious Gravity 5 3 instances 3 exposed
Issued
Mar 26, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage:    a) Agent 1 office - On or about 3/5/2013, bags stored on the floor presented tripping hazards.    b) Safety office - On or about 3/5/2013, a box and piles of papers were sorted on the floor and posed tripping hazards.    c) Resident Agent In Charge office - On or about 3/5/2013, a box and piles of papers were stored on the floor and posed tripping hazards.
Recent events (1)
  • · Z (S) $0

1910.303 B01 II

Serious Gravity 5 2 instances 22 exposed
Issued
Mar 26, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    a) Telecommunications room - On or about 3/5/2013, an electrical outlet was not protected by a faceplate    b) Kitchen - On or about 3/5/2013, an electrical outlet was not protected by a faceplate.
Recent events (1)
  • · Z (S) $0

1910.303 B02

Serious Gravity 5 3 instances 22 exposed
Issued
Mar 26, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Live animal room - On or about 3/5/2013, an extension cord was daisy-chained to a surge protector.    b) Admin support cubicle - On or about 3/5/2013, two surge protectors were daisy-chained together.    c) Agent 2 office - On or about 3/5/2013, an extension cord was daisy-chained to a surge protector.
Recent events (1)
  • · Z (S) $0

1910.303 G01 II

Serious Gravity 5 2 instances 1 exposed
Issued
Mar 26, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    a) Supply room - On or about 3/5/2013, the area in front of an electrical panel was used to store a paper shredder.    b) Small storage room - On or about 3/5/2013, the area in front of an electrical panel was used to store a plastic bin,  vacuum cleaner, and a trash can.
Recent events (1)
  • · Z (S) $0

1910.305 A02 X

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:    Inspector  2 cubicle - On or about 3/5/2013, an electrical cord was connected at a sharp angle that could cause breaks in the insulation.
Recent events (1)
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 2 instances 22 exposed
Issued
Mar 26, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a) Live animal room - On or about 3/5/2013, an extension cord was used as permanent wiring.    b) Agent 2 office - On or about 3/5/2013, an extension cord was used as permanent wiring.
Recent events (1)
  • · Z (S) $0

1910.1200 F05 I

Serious Gravity 1 2 instances 18 exposed
Issued
Mar 26, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:    a) In the Live animal room - On or about 3/5/2013, a spray bottle was not labeled with its chemical contents.	    b) In the Small storage room - On or about 3/5/2013, solvent and cleaning oil bottles were not labeled with its chemical contents.