Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: RAZOR COMPOSITES, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of RAZOR COMPOSITES, LLC in 1315 LAKE STREET, BARABOO, WI 53913 (NAICS 326199). OSHA activity number 338944242.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Razor Composites, LLC for free Get an email when a new federal OSHA severe-injury report for Razor Composites, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1315 LAKE STREET
City
BARABOO
State
WI
ZIP
53913
Mailing
P.O. BOX 759, BARABOO, WI 53913
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
61
Ownership type
Private (A)

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 1 exposed
Issued
Jul 10, 2013
Abate by
Dec 31, 2013
Penalty
Initial $5,000 · Current $2,500 Reduced
OSH ACT of 1970 Section (5)(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to combustible fiberglass/resin dust explosion, deflagration, or other fire hazards while working at or near dust collection system which was not adequately designed to prevent or minimize employee exposure in the event of a deflagration or other uncontrolled fire event:   On or about March 6, 2013   a) The outside Dust Control media-type and cyclone dust collectors handling combustible fiberglass/resin dust lacked a means of a deflagration propagation isolation to prevent the potential propagation of a deflagration, originating from the outside dust collectors, back into the workplace.    Among other methods, one feasible means of abatement to correct this hazard would be to comply with The National Fire Protection Association (NFPA) 654 "Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids, 2013 ed.", section 7.1.6 and 7.1.7 by installing a listed deflagration isolation device in a safe location/manner downstream of the process and upstream of the outdoor dust collectors in accordance with NFPA 69, "Standard on Explosion Prevention Systems."  Installing explosion protection systems on the outdoor dust collectors, in addition to an isolation device, is an additional recognized practice which may further reduce the hazard.
Recent events (3)
  • · F (S) $2500
  • · C (S) $5000
  • · Z (S) $5000

1910.147 C01

Other-than-serious 1 instance 1 exposed
Issued
Jul 10, 2013
Abate by
Aug 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  A lockout/tagout program was not developed for the Pulltrusion lines including saws and other equipment.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Jul 10, 2013
Abate by
Aug 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.  Fork truck drivers were not evaluated every three years.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338944242.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.