BOARDMAN, OR —
OSHA Inspection: MORROW COUNTY GRAIN GROWERS, INC, BOARDMAN ELEVATOR
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MORROW COUNTY GRAIN GROWERS, INC, BOARDMAN ELEVATOR in 71010 RAIL LOOP DRIVE, BOARDMAN, OR 97818 (NAICS 424510). OSHA activity number 338945462.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MORROW COUNTY GRAIN GROWERS, INC, BOARDMAN ELEVATOR
- Site address
- 71010 RAIL LOOP DRIVE
- City
- BOARDMAN
- State
- OR
- ZIP
- 97818
- Mailing
- 350 MAIN STREET PO BOX 367, LEXINGTON, OR 97839
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 8
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 E01
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.134(e)(1) is applicable to employment by 29 CFR 1917.1(a)(2)(x) that incorporates the General Industry requirement: The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) An employee was potentially exposed to health risks from the use of a full-face tight-fitting respirator before undergoing a medical evaluation. Located at the Boardman Terminal at 71010 Rail Loop Drive in Boardman, Oregon.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.134 F02
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2) is applicable to employment by 29 CFR 1917.1(a)(2)(x) that incorporates the General Industry requirement: Employee(s) using a tight-fitting facepiece respirator were not annually fit tested or were not fit tested prior to initial use of the respirator: (a) On or about March 7, 2013 the inspection revealed that the employer required employees to use tight-fitting respirators and that employees either were not fit tested prior to initial use or were not fit tested annually. Located at the Boardman Elevator at 71010 Rail Loop Drive in Boardman, Oregon.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.272 J01
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.272(j)(1): The employer did not develop and implement a written housekeeping program that established the frequency and the method(s) determined best to reduce accumulations of fugitive grain dust on ledges, floors, equipment, and other expose (a) On or about March 7, 2013 the inspection revealed that the employer did not develop a written housekeeping program. The location is a grain elevator with a bucket elevator system that is used to move corn and wheat and is located 71010 Rail Loop Drive in Boardman, Oregon.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B07 IV
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv) is applicable to employment by 29 CFR 1917.1(a)(2)(iv) that incorporates the General Industry requirement: There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemcial action or overheating: (a) The inspection revealed stop/start buttons with damaged outer covers. The buttons were the main power shutoff for the grain spout conveyor and were located at the west end of the catwalk leading to the grain spout at the Boardman Terminal, 71010 Rail Loop Drive in Boardman, Oregon. (b) The inspection revealed stop/start buttons with damaged outer covers. The buttons were located at the uppermost catwalk of the Boardman Terminal Grain Elevator just east of the access man elevator. (c) The inspection revealed stop/start buttons with damaged outer coversstop/start buttons with damaged outer covers. The buttons were located at the uppermost catwalk of the Boardman Terminal Grain Elevator at the far east end.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1917.26 B
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1917.26(b): At least one person holding a valid first aid certificate shall be at the terminal when work is in progress. (a) On or about March 7, 2013 the inspection revealed that the employer did not ensure that at least one person holding a valid first aid certificate was at the terminal when work was in progress. Located at the Boardman elevator in 71010 Rail Loop Drive in Boardman, Oregon.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1917.26 D02
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1917.26(d)(2): Stretchers were not kept in close vicinity of the vessel and/or positioned so as to avoid damage to the stretcher. (a) On or about March 7, 2013 the inspection revealed that the stokes basket stretcher was not kept in close vicinity of the grain terminal loading spout. Located at the Boardman Elevator at 71010 Rail Loop Drive in Boardman, Oregon.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1917.152 D05
- Issued
- Mar 25, 2013
- Abate by
- Apr 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1917.152(d)(5): Pressure regulators, including associated gauges, were not maintained in safe working order: (a) The inspection revealed an oxy-acetylene cutting torch with a damaged acetylene gauge. The cutting torch was located in the shop at the Boardman Terminal at 71010 Rail Loop Drive in Boardman, Oregon.