Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE HIBBERT GROUP

Foreign inspection · Health discipline

On , OSHA opened a foreign health inspection of THE HIBBERT GROUP in 1100 ROUTE 130 SOUTH POB 8116, ROBBINSVILLE, NJ 08691 (NAICS 541613). OSHA activity number 338950702.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Hibbert Group — free Get an email when a new federal OSHA severe-injury report for The Hibbert Group is published. One employer, no account, unsubscribe in one click.
Establishment
THE HIBBERT GROUP
Site address
1100 ROUTE 130 SOUTH POB 8116
City
ROBBINSVILLE
State
NJ
ZIP
08691
Mailing
1100 ROUTE 130 SOUTH POB 8116, ROBBINSVILLE, NJ 08691
Inspection type
Foreign (L)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541613
Employees
55
Ownership type
A

2 citations on file for this inspection.

1910.178 G02

Serious Gravity 1 4 instances 6 exposed
Issued
Apr 16, 2013
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.178(g)(2):     Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks:    a) Warehouse Area-Receiving Department: On or about 03/12/13, the battery charging apparatus for Hawker Power Guard Industrial Battery Charger (M#PH3R-12-865; S# 49949J04) was not protected from damage by trucks resulting in the charging cord wires being damaged and held together by electrical tape.    b) Warehouse Area-Receiving Department: On or about 03/12/13, the battery charging apparatus for Hawker Power Guard Industrial Battery Charger (M#PH3R-12-865; S# 49950J04) was not protected from damage by trucks resulting in the charging cord wires being damaged and held together by electrical tape.    c) Warehouse Area-Receiving Department: On or about 03/12/13, the battery charging apparatus for Hawker Power Guard Industrial Battery Charger (M#PH3R-12-865; S# 49951J04) was not protected from damage by trucks resulting in the charging cord wires being damaged and held together by electrical tape.    d) Warehouse-Charging Area: On or about 03/12/13, the battery charging apparatus for Hawker Power Guard Industrial Battery Charger (M#PH3R-18-775; S# 49948J04) was not protected from damage by trucks resulting in the charging cord wires being damaged and held together by electrical tape.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.303 B01 II

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 16, 2013
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.303(b)(1)(ii):     Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:    a) Warehouse-Charging Area: On or about 03/12/13, the Hawker Power Guard Industrial Battery Charger (M#PH3R-18-775; S# 49948J04) was being operated while the conductor running from the junction box to the charging unit had its insulation damaged thus exposing the wires contained within the conductor.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

View The Hibbert Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338950702.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.