OSHA Inspection: ALL SAFE FIRE PROTECTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALL SAFE FIRE PROTECTION, INC. in 4100 ALBANY POST RD., PEEKSKILL, NY 10566 (NAICS 238220). OSHA activity number 338951130.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ALL Safe Fire Protection, INC. — free Get an email when a new federal OSHA severe-injury report for ALL Safe Fire Protection, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4100 ALBANY POST RD.
City
PEEKSKILL
State
NY
ZIP
10566
Mailing
835 FRANKLIN AVE., THORNWOOD, NY 10594
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 21, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    Location: canopy  On or about: 3/11/13    a) Employees, replacing heat detectors on the fire suppression system, were not provided with fall protection. The employees were exposed to a fall of 16 feet 5 inches.    NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1926.503 A01

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 21, 2013
Abate by
Aug 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards:    Location: canopy  On or about: 3/11/13    a) Employees, exposed to a fall hazard while replacing heat detectors on the fire suppression system, were not provided with fall protection training.     NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View ALL Safe Fire Protection, INC.'s full OSHA safety record →