WARRENDALE, PA ·
OSHA Inspection: OWL CLEANERS
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of OWL CLEANERS in 165 NORTHGATE DRIVE, WARRENDALE, PA 15086 (NAICS 812310). OSHA activity number 338951312.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OWL CLEANERS
- Site address
- 165 NORTHGATE DRIVE
- City
- WARRENDALE
- State
- PA
- ZIP
- 15086
- Mailing
- 165 NORTHGATE DRIVE, WARRENDALE, PA 15086
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812310
- Employees
- 28
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.101 B
- Issued
- Apr 5, 2013
- Abate by
- Apr 24, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: (a) Facility - 165 Northgate Drive, Warrendale, PA: On or about March 12, 2013, three compressed gas cylinders were observed in the work area and not secured.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.147 C01
- Issued
- Apr 5, 2013
- Abate by
- Jun 3, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Facility - 165 Northgate Drive, Warrendale, PA: On or about March 12, 2013, an employee performs repairs and maintenance on equipment in the facility and the employer had not developed an energy control program.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.212 A01
- Issued
- Apr 5, 2013
- Abate by
- May 1, 2013
- Penalty
- Initial $4,200 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Facility - 165 Northgate Drive, Warrendale, PA: On or about March 12, 2013, employees are working with and near the screw conveyor that has rotating parts and ingoing nip points that were not properly guarded.
Recent events (2)
- · I (S) $2520
- · Z (S) $4200
1910.305 B02 I
- Issued
- Apr 5, 2013
- Abate by
- Apr 17, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) Facility - 165 Northgate Drive, Warrendale, PA: On or about March 12, 2013, employees working in the boiler room were exposed to electrical wiring from junction boxes without the covers in place.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.305 G01 IV A
- Issued
- Apr 5, 2013
- Abate by
- Apr 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Facility - 165 Northgate Drive, Warrendale, PA: On or about March 12, 2013, an extension cord was being used to power the control valves in the boiler room.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G02 III
- Issued
- Apr 5, 2013
- Abate by
- Apr 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Facility - 165 Northgate Drive, Warrendale, PA: On or about March 12, 2013, an extension cord was observed with wiring exposed and no strain relief present.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B02
- Issued
- Apr 5, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Facility - 165 Northgate Drive, Warrendale, PA: On or about March 12, 2013, a lighting ballast had exposed wiring and was not installed in accordance with the listed or labeling requirements.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at OWL Cleaners
View OWL Cleaners's full OSHA safety record →
More inspections in this industry (NAICS 812310)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338951312.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.