BATAVIA, NY ·
OSHA Inspection: AUTOMOTIVE CORPORATION INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AUTOMOTIVE CORPORATION INC in 4320 FEDERAL DRIVE, BATAVIA, NY 14020 (NAICS 336399). OSHA activity number 338953649.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AUTOMOTIVE CORPORATION INC
- Site address
- 4320 FEDERAL DRIVE
- City
- BATAVIA
- State
- NY
- ZIP
- 14020
- Mailing
- 4320 FEDERAL DRIVE, BATAVIA, NY 14020
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336399
- Employees
- 140
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.305 B01 II
- Issued
- Mar 20, 2013
- Abate by
- Apr 11, 2013
- Penalty
- Initial $2,295 · Current $1,721 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed: a) On or about 03/06/2013 in the maintenance shop; where there was a missing "knockout" on a bench mounted, metal duplex receptacle box. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1721.25
- · Z (S) $2295
1910.335 A01 I
- Issued
- Mar 20, 2013
- Abate by
- May 2, 2013
- Penalty
- Initial $3,825 · Current $2,869 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with, and did not use, electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: a) On or about 03/06/2013 throughout establishment; where electricians are exposed/potentially exposed to electrical arc flash hazards while performing "live" electrical work such as, but not limited to troubleshooting electrical circuits. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $2868.75
- · Z (S) $3825
1910.147 C05 II
- Issued
- Mar 20, 2013
- Abate by
- Apr 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were utilized for other purposes than controlling energy: a) On or about 03/06/2013 in the maintenance shop; where a "lockout lock" was used to lock a tool box closed. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Automotive Corporation INC
View Automotive Corporation INC's full OSHA safety record →
More inspections in this industry (NAICS 336399)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338953649.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.