OSHA Inspection: VAILLANCOURT ELECTRIC SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VAILLANCOURT ELECTRIC SERVICE in COMMUNITY STREET, BERLIN, NH 03570 (NAICS 238210). OSHA activity number 338954092.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vaillancourt Electric Service for free Get an email when a new federal OSHA severe-injury report for Vaillancourt Electric Service is published. One employer, no account, unsubscribe in one click.
Site address
COMMUNITY STREET
City
BERLIN
State
NH
ZIP
03570
Mailing
244 GLEN AVE, BERLIN, NH 03570
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
20
Ownership type
Private (A)

7 citations on file for this inspection.

1926.95 A

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Sep 10, 2013
Abate by
Sep 16, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition:  (a) Transformer Yard  Employees were exposed to electrical shock hazards while working on live 480 volt panel without any personal protective equipment.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1926.416 A01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Sep 10, 2013
Abate by
Sep 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  (a) Transformer Yard  Employees were exposed to an electrical shock hazard while working on unguarded electrical equipment.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.403 H

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Sep 10, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.403(h): Each service, feeder, and branch circuit was not legibly marked at its disconnecting means or overcurrent device to indicate its purpose, nor located and arranged so that the purpose was evident:ALLEGED VIOLATION DESCRIPTION (A.V.D.):   Reclaimer Tunnel  The circuit breakers in the electrical service panel were not labeled as to their use.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1926.405 A02 II C

Deleted Serious Gravity 1 2 instances 4 exposed
Issued
Sep 10, 2013
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.405(a)(2)(ii)(C): Receptacles for uses other than temporary lighting were installed on branch circuits which supplied temporary lighting:    (a) Site - Employees were not protected from slips, trips, and falls when the temporary lighting throughout the site was connected to the same GFCI outlets that were being used to power hand tools.     (b) Re-claimer Tunnel  The temporary lights were not installed on dedicated circuits.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1200

1926.405 B01

Deleted Serious Gravity 5 2 instances 5 exposed
Issued
Sep 10, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.405(b)(1): Openings in boxes, cabinets, and fittings through which conductors entered were not effectively closed:   (a) Boiler Room Building, 1st Floor - Employees were not protected from electrical shocks and burns when the cabinet for the temporary electric panel contained unused openings that were not effectively closed.       (b) Re-claimer Tunnel  The main electrical service panel had unused openings.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

1926.405 G02 IV

Deleted Serious Gravity 5 2 instances 500 exposed
Issued
Sep 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:   a. Boiler Room Building, 1st Floor - Employees were not protected from electrical shocks and burns when flexible cords exiting the temporary electric cabinet were not provided with strain relief resulting in two cords having exposed live wiring.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.405 E01

Deleted Serious Gravity 10 1 instance 500 exposed
Issued
Sep 10, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.405(e)(1): Panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures:   a. Boiler Room Building - Employees were not protected from electrical shocks and burns when the electric panel for the temporary power was not weatherproof and was located beneath a floor drain which poured water directly onto the cabinet.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338954092.