Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: WEISER ENGINEERING/MILE HIGH PRECISION INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of WEISER ENGINEERING/MILE HIGH PRECISION INC. in 10901 IRMA DRIVE, NORTH GLENN, CO 80233 (NAICS 332322). OSHA activity number 338956360.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Weiser Engineering/Mile High Precision INC. for free Get an email when a new federal OSHA severe-injury report for Weiser Engineering/Mile High Precision INC. is published. One employer, no account, unsubscribe in one click.
Site address
10901 IRMA DRIVE
City
NORTH GLENN
State
CO
ZIP
80233
Mailing
10901 IRMA DRIVE, NORTH GLENN, CO 80234
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
45
Ownership type
A

7 citations on file for this inspection.

1910.132 A

Serious Gravity 1 1 instance 2 exposed
Issued
May 16, 2013
Abate by
Jun 20, 2013
Penalty
Initial $1,785 · Current $982 Reduced
29 CFR 1910.132(a):  Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    (a) Weiser Engineering/Mile High Precision Inc, at 10901 Irma Drive, Northglenn, CO: On and preceding 3/19/13, Weiser Engineering/Mile High Precision Inc did not ensure that protective equipment was used when necessary whenever hazards capable of causing injury and impairment were encountered.  Employees assisted the forklift operator with loading and unloading trucks in the paved area between the facility's two buildings.  Building lighting did not provide adequate lighting for the traffic area.  The employer did not ensure that protective equipment in the form of high visibilty clothing was used by employees who worked in the yard or in proximity to operation of the powered industrial truck.  This condition exposed employees to a struck-by hazard.
Recent events (2)
  • · I (S) $982
  • · Z (S) $1785

1910.178 L04 III

Serious Gravity 1 1 instance 3 exposed
Issued
May 16, 2013
Abate by
Jun 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): The employer did not ensure that each powered industrial truck operator's performance was evaluated at least once every three years:  (a) Weiser Engineering/Mile High Precision Inc, at 10901 Irma Drive, Northglenn, CO: On and preceding 3/19/13, Weiser Engineering/Mile High Precision Inc did not ensure that each powered industrial truck operator's performance was evaluated at least once every three years.  Employees operated a Hyster model 60 powered industrial truck while loading and unloading trucks in the paved area between the facility's two buildings.  The employer did not evaluate each powered industrial truck operator's performance at least once every three years.  This condition exposed employees to a struck-by hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 F02

Serious Gravity 1 1 instance 3 exposed
Issued
May 16, 2013
Abate by
Jun 20, 2013
Penalty
Initial $1,785 · Current $982 Reduced
29 CFR 1910.178(f)(2): The storage and handling of liquefied petroleum gas fuel was not in accordance with NFPA 58-1969 "Storage and Handling of Liquefied Petroleum Gases":    (a) Weiser Engineering/Mile High Precision Inc, at 10901 Irma Drive, Northglenn, CO: On and preceding 3/19/13, Weiser Engineering/Mile High Precision Inc did not ensure that the storage and handling of liquefied petroleum gas fuel was in accordance with NFPA 58-1969 "Storage and Handling of Liquefied Petroleum Gases".  Employees operated a Hyster model 60 powered industrial truck while loading and unloading trucks in the paved area between the facility's two buildings.  The powered industrial truck was propane fueled.  Full and empty propane gas cylinders were stored inside the building that housed the shipping department.  The cylinders were adjacent to the building large overhead door which was used by forklift and pedestrian traffic.  The employer did not ensure that propane gas cylinders were stored in accordance with NFPA 58-1969.  This condition exposed employees to a fire or explosion hazard.
Recent events (2)
  • · I (S) $982
  • · Z (S) $1785

1910.1200 E01

Serious Gravity 1 1 instance 45 exposed
Issued
May 16, 2013
Abate by
Jun 20, 2013
Penalty
Initial $1,785 · Current $981 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at least describes how the criteria in 29 CFR 1910.1200(f), (g) and (h) will be met:    (a) Weiser Engineering/Mile High Precision Inc, at 10901 Irma Drive, Northglenn, CO: On and preceding 3/19/13, Weiser Engineering/Mile High Precision Inc had not developed or implemented a written hazard communication program which at least describes how the criteria in 29 CFR 1910.1200(f), (g) and (h) will be met.  Hazardous chemicals located in the workplace included, but are not limited to the following:    1.  Propane;  2.  Hobart Brothers carbon steel welding electrodes;  3.  AlcoTec Aluminum welding wire;  4.  Inweld stainless steel welding rod;  5.  Magnaflux Spotcheck Developer SKD-S2; and   6.  Acetone.
Recent events (2)
  • · I (S) $981
  • · Z (S) $1785

1910.1200 H01

Serious Gravity 1 1 instance 45 exposed
Issued
May 16, 2013
Abate by
Jul 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area:    (a) Weiser Engineering/Mile High Precision Inc, at 10901 Irma Drive, Northglenn, CO: On and preceding 3/19/13, Weiser Engineering/Mile High Precision Inc did not ensure that employees were provided effective information and training as specified in 29 CFR 1910.1200(h) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area.  Hazardous chemicals located in the workplace included, but are not limited to the following:    1.  Propane;  2.  Hobart Brothers carbon steel welding electrodes;  3.  AlcoTec Aluminum welding wire;  4.  Inweld stainless steel welding rod;  5.  Magnaflux Spotcheck Developer SKD-S2; and   6.  Acetone.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 E01

Other-than-serious 1 instance 2 exposed
Issued
May 16, 2013
Abate by
Jun 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested, or required to use the respirator in the workplace:  (a) Weiser Engineering/Mile High Precision Inc, at 10901 Irma Drive, Northglenn, CO: On and preceding 3/19/13, Weiser Engineering/Mile High Precision Inc did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested, or required to use the respirator in the workplace.  Employees welded carbon steel, aluminum, and stainless steel.  Employees were required to wear Kimberly-Clark Professional Jackson Safety Airmax helmet powered air purifying respirators with high efficiency filter.  The employer did not ensure that all employees were provided with a medical evaluation to determine the employee's ability to use a respirator.  This condition potentially exposed employees to a respiratory hazard.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 K01

Other-than-serious 1 instance 2 exposed
Issued
May 16, 2013
Abate by
Jun 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1): The employer did not provide effective, comprehensive, understandable, annual respirator training to employees who are required to use respirators:  (a) Weiser Engineering/Mile High Precision Inc, at 10901 Irma Drive, Northglenn, CO: On and preceding 3/19/13, Weiser Engineering/Mile High Precision Inc did not provide effective, comprehensive, understandable, annual respirator training to employees who are required to use respirators.    Employees welded carbon steel, aluminum, and stainless steel.  Employees were required to wear Kimberly-Clark Professional Jackson Safety Airmax helmet powered air purifying respirators with high efficiency filter.  The employer did not provide annual comprehensive respirator training.  This condition potentially exposed employees to a respiratory hazard.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Weiser Engineering/Mile High Precision INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338956360.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.