OSHA Inspection: LIPSON ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LIPSON ROOFING in 3181 LINCOLN HIGHWAY E, PARADISE, PA 17562 (NAICS 238160). OSHA activity number 338956550.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lipson Roofing for free Get an email when a new federal OSHA severe-injury report for Lipson Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
LIPSON ROOFING
Site address
3181 LINCOLN HIGHWAY E
City
PARADISE
State
PA
ZIP
17562
Mailing
402 W. CONESTOGA STREET, NEW HOLLAND, PA 17557
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 27, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.      a) 3181 Lincoln Highway E, Paradise PA 17562; Ladderjack Scaffold - Employees were observed working from a ladder jack scaffold 8 feet - 6 inches thru 22 feet - 3 inches above ground and were not provided safe access to the platform by the use of a portable ladder, on or about March 14, 2013.    No abatement certification or documentation required.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.452 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m):    a) 3181 Lincoln Highway E, Paradise PA 17562; Ladderjack Scaffold - Roofers were observed working from the platform of a ladder jack scaffold which measured 22 feet -  3 inches above ground, on or about March 14, 2013.     No abatement certification or documentation required.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 27, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     a) 3181 Lincoln Highway E, Paradise PA 17562; Upper Roof - Roofers were observed without fall protection while ripping off shingles from the roof of a residential home and were exposed to a fall hazard up to 22 foot - 3 inch fall hazard, on or about March 14, 2013.     b) 3181 Lincoln Highway E, Paradise PA 17562; Lower Roof - Roofers were observed without fall protection while walking across a lower roof to access a ladder jack scaffold and were exposed to a 12 foot - 10 inch fall hazard, on or about March 14, 2013.    No abatement certification or documentation required.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 27, 2013
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) 3181 Lincoln Highway E, Paradise PA 17562; Lower Roof - Roofers were observed using a portable extension ladder to gain access to a roof and the ladder extended approximately 6 inches above the landing surface exposing the roofers to a 12 foot - 10 inch fall hazard, on or about March 14, 2013.    No abatement certification or documentation required.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600