WASHINGTON, DC —
OSHA Inspection: DAFORE, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DAFORE, LLC in 660 7TH STREET, SE, WASHINGTON, DC 20024 (NAICS 238130). OSHA activity number 338956576.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAFORE, LLC
- Site address
- 660 7TH STREET, SE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20024
- Mailing
- 24 SYNAN ROAD, #107, FREDERICKSBURG, VA 22405
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 G01 II
- Issued
- Apr 4, 2013
- Abate by
- Apr 10, 2013
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system: a) Exterior Face of Building Between Roof and Third Floor - An employee was observed standing on a two point suspended scaffold work platform while attaching metal stud framing to the face of the building and a provided lifeline was not used, thus exposed to a 25 foot fall hazard, on or about March 13, 2013. b) Exterior Face of Building Between Roof and Third Floor - An employee was observed standing on a two point suspended scaffold work platform while attaching metal stud framing to the face of the building and was not provided a lanyard, thus exposed to a 25 foot fall hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1926.454 A
- Issued
- Apr 4, 2013
- Abate by
- Apr 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Exterior Face of Building Between Roof and Third Floor - Employees were not provided adequate training in recognizing hazards associated with using a two point suspension scaffold as evidenced by an employee on a two point suspension scaffold work platform 25 feet above a lower roof level and was not provided a lifeline to attach a lanyard and one employee on a two point suspended scaffold work platform without having a lanyard, on or about March 13, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Apr 4, 2013
- Penalty
- Initial $4,900 · Current $3,430 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Roof, North Side - Two employees were observed standing near the edge handing down cut pieces of metal stud to employees working below on a two point suspension scaffold work platform and exposed to a 30 foot fall hazard, on or about March 13, 2013. No abatement certification or documentation required.
Recent events (2)
- — I (S) $3430
- — Z (S) $4900
1926.503 A01
- Issued
- Apr 4, 2013
- Abate by
- Apr 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Roof North Side - A fall protection training program was not developed or implemented as evidenced by noted hazards such as but not limited to; employees performing work while standing at the edge of a roof and exposed to a 30 foot fall hazard, on or about March 13, 2013. Abatement documentation is required within 10 days after abatement date. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Apr 4, 2013
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Lower Roof East Side - Employees were using a 12 foot portable step ladder to gain access to an upper roof level and the ladder was 6 inches below the landing surface, on or about March 13, 2013. No abatement certification or documentation required.
Recent events (2)
- — I (O) $2450
- — Z (S) $3500
1926.1053 B04
- Issued
- Apr 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Lower Roof East Side - Employees were using a 12 foot portable stepladder that was folded and leaning against a wall, to gain access to a lower roof level, on or about March 13, 2013. No abatement certification or documentation required.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.1053 B13
- Issued
- Apr 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Lower Roof East Side - Employees were using the top step of a 12 foot portable step ladder to gain access to a lower roof level, on or about March 13, 2013. No abatement certification or documentation required.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Dafore, LLC
View Dafore, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338956576.