ARLINGTON HEIGHTS, IL —
OSHA Inspection: AMPCO METAL, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AMPCO METAL, INC. in 1117 E ALGONQUIN ROAD, ARLINGTON HEIGHTS, IL 60005 (NAICS 331525). OSHA activity number 338956824.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMPCO METAL, INC.
- Site address
- 1117 E ALGONQUIN ROAD
- City
- ARLINGTON HEIGHTS
- State
- IL
- ZIP
- 60005
- Mailing
- 1117 E. ALGONQUIN ROAD, ARLINGTON HEIGHTS, IL 60005
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331525
- Employees
- 35
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Apr 11, 2013
- Abate by
- May 7, 2013
- Penalty
- Initial $1,785 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition: a) Water Pump Room - A long piece of rubber hose was placed along a walkway and entrance door of the pump room where it caused a trip and fall hazard.
Recent events (2)
- — I (S) $1100
- — Z (S) $1785
1910.22 A02
- Issued
- Apr 11, 2013
- Abate by
- May 31, 2013
- Penalty
- Initial $1,785 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained, so far as possible, in a dry condition: a) Pump Room - Water leaking from pipes was spilled onto floor where employees work and walk causing slip and fall hazards.
Recent events (2)
- — I (S) $1100
- — Z (S) $1785
1910.212 A01
- Issued
- Apr 11, 2013
- Abate by
- May 17, 2013
- Penalty
- Initial $2,380 · Current $1,475 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Manual Machine Area - The employer had an Amada H 600 horizontal metal cutting band saw model #H-600, serial #555067, that did not have the unused portion of the blade guarded on both sides. b) Tool Room - The South Bend lathe serial #14251, was not equipped with an enclosure guard for the rotating chuck and chip guard to contain flying chips or sparks.
Recent events (2)
- — I (S) $1475
- — Z (S) $2380
1910.253 B02 II
- Issued
- Apr 11, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $2,380 · Current $1,475 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, and gangways, or where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) Outside Tool Room - Oxygen compressed cylinder tank was not secured from physical damage by passing or falling objects.
Recent events (2)
- — I (S) $1475
- — Z (S) $2380
1910.303 G02 I
- Issued
- Apr 11, 2013
- Abate by
- Apr 30, 2013
- Penalty
- Initial $2,975 · Current $1,850 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: a) First Floor Under Melter Deck - The employer had an electrical panel with with exposed buss bars that was not protected from accidental contact from employees. The electrical panel had its cover off and to the side of the floor. b) First Floor Under Melter Deck - The employer had an electrical panel with exposed buss bars that was not protected from accidental contact.
Recent events (2)
- — I (S) $1850
- — Z (S) $2975
More inspections at Ampco Metal, INC.
View Ampco Metal, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331525)
More inspections in IL