LAWTON, OK —
OSHA Inspection: COUNTER INTELLIGENCE, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of COUNTER INTELLIGENCE, INC. in 228 SE PARK AVENUE, LAWTON, OK 73501 (NAICS 327991). OSHA activity number 338956873.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COUNTER INTELLIGENCE, INC.
- Site address
- 228 SE PARK AVENUE
- City
- LAWTON
- State
- OK
- ZIP
- 73501
- Mailing
- 228 SE PARK AVENUE, LAWTON, OK 73501
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 7
- Ownership type
- A
Citations
21 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electric shock hazards. a. On or about 3/12/2013, shop, ground-fault circuit-interrupter protection for personnel was not used to power portable electric equipment such as an air handler, hand held electric grinders, and a Diarex router, used by employees who were likely to contact water during granite counter top fabrication which exposes employees to electric shock hazards.
Recent events (1)
- — Z (S) $2000
1910.305 B02 I
- Issued
- Jul 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a. On or about 3/12/2013, east side of the shop, an electrical box with energized electrical wires did not have a cover which exposes employees to electric shock hazards. b. On or about 3/12/2013, west side of the shop, an electrical box with energized electrical wires did not have a cover which exposes employees to electric shock hazards
Recent events (1)
- — Z (S) $0
1910.305 J02 VII
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(vii): A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use (for example, portable tools) did not have an enclosure that was weatherproof when the attachment plug cap was removed: a. On or about 3/12/2013, shop, west wall, an outlet receptacle at a bench did not have a weatherproof cover and water was present from granite counter top polishing which exposes employees to electric shock hazards. b. On or about 3/12/2013, shop, north wall, an outlet receptacle did not have a weatherproof cover and was near a wet saw used to by an employee to cut granite slabs which exposes an employee to electric shock hazards.
Recent events (1)
- — Z (S) $0
1910.334 A04
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(4): Conductive work locations. Portable electric equipment and flexible cords used in highly conductive work locations (such a those inundated with water or other conductive liquids), or in job locations where employees are likely to contact water or conductive liquids, were not approved for those locations: a. On or about 3/12/2013, shop, an air handler was not approved for wet locations and was used in the shop during wet operations such as a stone polishing with water which exposes employees to electric shock hazards.
Recent events (1)
- — Z (S) $0
1910.94 B04 III
- Issued
- Jul 17, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $2,000 · Current $2,000
9010
General-duty citation text
29 CFR 1910.94(b)(4)(iii): All exhaust systems were not provided with suitable dust collectors: a. On or about 3/12/13, shop, a dust collector was not used as part of the dust exhaust system for cutting granite slabs with a portable electric grinder which exposes employees to respiratory hazards such as Crystalline Silica (Quartz).
Recent events (1)
- — Z (S) $2000
1910.94 B05 IV
- Issued
- Jul 17, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $0 · Current $0
9010
General-duty citation text
29 CFR 1910.94(b)(5)(iv): Portable grinding operations whenever the nature of the work permits, shall be conducted within a partial enclosure: a. On or about 3/12/13, shop, an enclosure was not used as part of the dust exhaust system for cutting granite slabs with a portable electric grinder which exposes employees to respiratory hazards such as Crystalline Silica (Quartz).
Recent events (1)
- — Z (S) $0
1910.1000 C
- Issued
- Jul 17, 2013
- Abate by
- Jul 19, 2013
- Penalty
- Initial $0 · Current $0
9010
General-duty citation text
29 CFR 1910.1000(c): Table Z-3. An employee's exposure to any substance listed in Table Z-3, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in the table. a. On or about 3/13/2013, shop, an employee personal 8-hour time-weighted average (8-Hr TWA) exposure to respirable dust containing 15.3% Crystalline Silica Quartz was 1.158 mg/m3 during fabrication of granite counter tops. This exposure exceeded the OSHA 8-Hr TWA Crystalline Silica Quartz PEL of 0.579 mg/m3 by 2 times for respirable dust containing 15.3% Crystalline Silica Quartz. The personal air monitoring consisted of two samples collected during a 151 minute sampling period on 3/13/2013. The remaining un-sampled time of 329 minutes was included in the 8-Hr TWA as a zero exposure period. b. On or about 3/13/2013, shop, an employee personal 8-hour time-weighted average (8-Hr TWA) exposure to respirable dust containing 15.5% Crystalline Silica Quartz was 0.805 mg/m3 during fabrication of granite counter tops. This exposure exceeded the OSHA 8-Hr TWA Crystalline Silica Quartz PEL of 0.571 mg/m3 by 1.4 times for respirable dust containing 15.5% Crystalline Silica Quartz. The personal air monitoring consisted of three samples collected during a 450 minute sampling period on 3/13/2013. The remaining un-sampled time of 30 minutes was included in the 8-Hr TWA as a zero exposure period.
Recent events (1)
- — Z (S) $0
1910.1000 E
- Issued
- Jul 17, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $0 · Current $0
9010
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): a. On or about 3/13/2013, Shop, administrative or engineering controls were not first determined and implemented for granite counter top installer/fabricator employees exposed to Crystalline Silica (Quartz) which includes but is not limited to the following: 1. Wet cutting of granite slabs. 2. Increase contaminant capture velocity at the point of dust generation. 3. Increase dilution ventilation by opening doors and windows. 4. Use HEPA filter within local exhaust ventilation to effectively capture crystalline silica containing dust.
Recent events (1)
- — Z (S) $0
1910.95 C01
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a. On or about March 13, 2013, shop, a hearing conservation program was not administered for a wet saw operator exposed to workplace noise at an 8-hour time-weighted average sound level of 88.7 dBA or, equivalently, a noise dose of 83.8% which exceeded the 8-hour time-weighted average of 85 dBA or equivalently a noise dose of 50%. The noise monitoring result was derived from a personal sampling time of 463 minutes and a non-sampled time of 17 minutes was a zero noise exposure period.
Recent events (1)
- — Z (S) $2000
1910.134 C01
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $2,000 · Current $2,000
9010
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. On or about 3/12/13, shop, a written respiratory protection program was not developed for employees who fabricate granite counter tops which exposes employees to respiratory hazards which include but are not limited to Crystalline Silica (Quartz).
Recent events (1)
- — Z (S) $2000
1910.134 E01
- Issued
- Jul 17, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $0 · Current $0
9010
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. On or about 3/12/13, shop, medical evaluations for respirator use were not provided to employees who used dust mask respirators or half mask respirators during fabrication of granite counter tops which exposes employees to respiratory hazards which include but are not limited to Crystalline Silica (Quartz).
Recent events (1)
- — Z (S) $0
1910.134 F02
- Issued
- Jul 17, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $0 · Current $0
9010
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a. On or about 3/12/13, shop, respirator fit testing was not provided to employees who used dust mask respirators or half mask respirators during fabrication of granite counter tops which exposes employees to respiratory hazards which include but are not limited to Crystalline Silica (Quartz).
Recent events (1)
- — Z (S) $0
1910.134 H04
- Issued
- Jul 17, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(4): Respirators that failed an inspection or were otherwise found to be defective were not removed from service and discarded or repaired: a.On or about 3/12/13, shop, a half mask MSA respirator was not taken out of service when it had missing inhalation valves and a stretched elastic strap. An employee used the respirator during fabrication of granite counter tops which exposes the employee to respiratory hazards which include but are not limited to crystalline silica.
Recent events (1)
- — Z (S) $0
1910.134 K
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: a. On or about 3/12/13, shop, the employer did not provide effective respirator training to employees who fabricate granite counter tops which exposes employees to respiratory hazards which include but are not limited to crystalline silica.
Recent events (1)
- — Z (S) $0
1910.243 C01
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4) a. On or about 3/12/13, Shop, an electric hand held grinder did not have a guard for the abrasive wheel used to cut out sink openings from granite counter tops which exposes employees to struck-by hazards.
Recent events (1)
- — Z (S) $2000
1910.303 F02
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a. On or about 3/12/2013, northeast corner of shop, a circuit breaker panel was not labeled to indicate what each circuit breaker controlled which exposes employees to electric shock hazards.
Recent events (1)
- — Z (S) $2000
1910.305 G01 IV A
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. On or about 3/12/2013, Shop, an orange extension cord that powered an overhead receptacle, was attached to an overhead horizontal beam and was used in lieu of fixed wiring which exposes employees to electric shock hazards.
Recent events (1)
- — Z (S) $0
1910.334 A02 II
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: a. On or about 3/12/2013, shop, a yellow extension cord had a break in its outer jacket which exposes employees to electric shock hazards. b. On or about 3/12/2013, shop, a black flexible cord for a refrigerator had a loose prong at the cord plug and the cord plug had a melted area which exposes employees to electric shock hazards. c. On or about 3/12/2013, shop, a black flexible cord for a router had a break in its outer jacket which exposes employees to electric shock hazards. d. On or about 3/12/2013, shop, a 4 outlet receptacle face was broken which exposes employees to electrical shock hazards.
Recent events (1)
- — Z (S) $0
1910.1200 E01
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. On or about March 12, 2013, shop, a written hazard communication program containing a list of the hazardous chemicals known to be present was not developed and implemented for employees who worked with hazardous chemicals which included but are not limited to the following: 1. Granite (crystalline silica containing) 2. Abrasive grinding discs (crystalline silica containing) 3. Wax (irritant) 4. Propane (flammable gas)
Recent events (1)
- — Z (S) $1600
1910.1200 G01
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: a. On or about March 12, 2013, Shop, safety data sheets were not available in the workplace for hazardous chemicals known to be present and used by employees for granite counter top fabrication which included but are not limited to the following: 1. Granite (crystalline silica containing) 2. Abrasive grinding discs (crystalline silica containing) 3. Wax (irritant) 4. Propane (flammable gas)
Recent events (1)
- — Z (S) $0
1910.1200 H01
- Issued
- Jul 17, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $0 · Current $0
9010
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. On or about March 12, 2013, shop, The employer did not provide employees with effective information and training on the hazardous chemicals in the work place for fabrication of granite counter tops which included but are not limited to the following: 1. Granite (crystalline silica containing) 2. Abrasive grinding discs (crystalline silica containing) 3. Wax (irritant) 4. Propane (flammable gas)
Recent events (1)
- — Z (S) $0
More inspections at Counter Intelligence, INC.
View Counter Intelligence, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327991)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338956873.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.