OSHA Inspection: CLEAN AIR AMERICA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CLEAN AIR AMERICA, INC. in 7 SUPERIOR BLVD, ROME, GA 30161 (NAICS 333411). OSHA activity number 338960990.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clean AIR America, INC. for free Get an email when a new federal OSHA severe-injury report for Clean AIR America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7 SUPERIOR BLVD
City
ROME
State
GA
ZIP
30161
Mailing
7 SUPERIOR BLVD, ROME, GA 30161
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333411
Employees
25
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 12, 2013
Abate by
Aug 29, 2013
Penalty
Initial $1,700 · Current $1,020 Reduced
29 CFR 1910.212(a)(1):  Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:   a) Welding area; Employees operated a Central machinery 20 production Drill press #39955 without a chuck guard, exposing employees to amputation hazards.
Recent events (2)
  • · I (S) $1020
  • · Z (S) $1700

1910.110 F02 II

Serious Gravity 5 1 instance 8 exposed
Issued
Aug 12, 2013
Abate by
Aug 29, 2013
Penalty
Initial $1,156 · Current $694 Reduced
29 CFR 1910.110(f)(2)(ii): 29 CFR 1910.110(f)(2)(ii):  LP gas container(s) stored inside were located near or in area(s) normally used or intended for the safe exit of employees:  a) Front shop gas cylinder area near exit, Employees enter and exit near LP gas contaners exposing employees to explosion and struck by hazards in the event of a fire.
Recent events (2)
  • · I (S) $693.6
  • · Z (S) $1156

1910.253 B02 IV

Serious Gravity 5 1 instance 8 exposed
Issued
Aug 12, 2013
Abate by
Aug 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  (a) Front of shop gas cylinder area; Employees were entering and exiting  door  within 10 feet of cylinders without caps being properly secured, exposing employees to struck by hazards
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 12, 2013
Abate by
Aug 29, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating:   (a) Front of shop gas cylinder area, Employees were exposed to oxygen and gas cylinders that were not seperated by 20 feet or more exposing employees to fire hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338960990.