Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: ATHENS' BEST, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of ATHENS' BEST, INC. in 2175 W. BROAD STREET, ATHENS, GA 30607 (NAICS 339950). OSHA activity number 338961568.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Athens' Best, INC. for free Get an email when a new federal OSHA severe-injury report for Athens' Best, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ATHENS' BEST, INC.
Site address
2175 W. BROAD STREET
City
ATHENS
State
GA
ZIP
30607
Mailing
2175 W. BROAD ST., ATHENS, GA 30606
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
9
Ownership type
Private (A)

7 citations on file for this inspection.

1910.106 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2013
Abate by
Oct 7, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.106(d)(4)(i): Inside storage rooms were not constructed to meet the required fire-resistive rating for their use.  The room was not made of noncombustible material.  The openings were not provided with approved self-closing fire doors.  Ventilation was not provided:      a) Employees are exposed to fire hazards in that the inside paint storage room used to store flammable paints was not constructed to meet the required fire resistive rating in that the walls were made of plywood, the door opening was made of wood, and there was no ventilation on or about 3/18/2013.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $2000

1910.106 D04 III

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2013
Abate by
Nov 20, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.106(d)(4)(iii): Electrical wiring and equipment located in inside storage rooms was not approved under subpart S of this part for Class I, Division 2 Hazardous Locations:    a) Employees are exposed to fire hazards in that the inside storage room wiring (lights, electrical outlets, etc.) was not approved for the location (Class I, Division 2) on or about 3/18/2013.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

1910.106 D04 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2013
Abate by
Nov 20, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.106(d)(4)(iv): Each inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system designed to provide for a complete change of air within the room at least six times per hour:    a) Employees are exposed to fire hazards in that the inside storage room did not have a gravity or mechanical exhaust ventilation system, on or about 3/18/2013.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

1910.303 G02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2013
Abate by
Aug 30, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):   a)Employees are exposed to an electrical shock hazard in the production area.  The two electrical light switches did not have covers exposing employees to live parts, on or about 3/18/13.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1910.1200 H01

Other-than-serious 1 instance 2 exposed
Issued
Aug 20, 2013
Abate by
Sep 5, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:     a) Employees are assigned tasks to weld and paint metal parts with hazardous chemicals. Chemicals include, but are not limited to paints, primers, xylene, and carbon steel. Employees had not been trained on the hazards of the chemicals in the workplace as required by this section, on or about 03/18/13.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (O) $800
  • · Z (S) $1600

1910.107 G07

Repeat 1 instance 2 exposed
Issued
Aug 20, 2013
Abate by
Aug 27, 2013
Penalty
Initial $80 · Current $0 Reduced
29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color backgrounds were not conspicuously posted at all spraying areas and the paint storage rooms:    a) The employer did not ensure that "No Smoking" signs were located within the paint storage areas where flammable chemicals were stored, on or about 3/18/2013.    The Athens' Best, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.107(g)(7), which was contained in OSHA inspection number 419883, citation number 1, item number 3 and was affirmed as a final order on 10/12/2012, with respect to a workplace located at 3495 Jefferson Road, Athens, Ga 30607.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (R) $0
  • · Z (R) $80

1910.134 H02 I

Other-than-serious 1 instance 1 exposed
Issued
Aug 20, 2013
Abate by
Aug 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:     a) An employee is required to wear a 3M full face respirator for painting.  The respirator was stored on a table in the production area on or about 3/18/2013.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).