Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HAVCO WOOD PRODUCTS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HAVCO WOOD PRODUCTS LLC in 3200 E. OUTER RD., SCOTT CITY, MO 63780 (NAICS 321918). OSHA activity number 338967599.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Havco Wood Products LLC — free Get an email when a new federal OSHA severe-injury report for Havco Wood Products LLC is published. One employer, no account, unsubscribe in one click.
Site address
3200 E. OUTER RD.
City
SCOTT CITY
State
MO
ZIP
63780
Mailing
P.O. BOX 1342, CAPE GIRARDEAU, MO 63702
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
306
Ownership type
A

4 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 1 instance 9 exposed
Issued
Apr 5, 2013
Abate by
Jun 13, 2013
Penalty
Initial $2,250 · Current $1,575 Reduced
29 CFR 1910.23(c)(1):     Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    a. In the loading area of the processing building, where product was loaded onto flatbed trucks without railing or other fall protection (truck beds 55-57 inches on two trucks in the building at the time of the inspection), employees loading and securing the load while standing on the truck bed and at somewhat higher heights when standing on the loaded product, were exposed to a fall.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2250

1910.169 B03 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 5, 2013
Abate by
Jun 13, 2013
Penalty
Initial $2,250 · Current $1,575 Reduced
29 CFR 1910.169(b)(3)(iv):     Safety valve(s) on compressed air receiver(s) were not tested at frequently regular intervals to determine if they were in good operating condition:    a. Where 5 gal air tanks were used for maintenance in the truck building, safety relief valves were not regularly tested.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2250

1910.304 G05

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 5, 2013
Abate by
Jun 13, 2013
Penalty
Initial $2,250 · Current $1,575 Reduced
29 CFR 1910.304(g)(5):     The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a. Examples existed of ground pins missing from equipment, such as, but not limited to, 110 V cooling fans with flexible power cords.    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2250

1910.147 C04 II

Other-than-serious 1 instance 4 exposed
Issued
Apr 5, 2013
Abate by
Dec 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii):     Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h):    a. Specific lockout procedures for each type of equipment where specific procedures were required, were not developed for all equipment, such as, but not limited to, the Putty Machine, Rex Machine, Plug Cutter, and Chop/Defect Saws (note: lockout was being performed and training had been provided).    Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0