WASHINGTON, DC —
OSHA Inspection: BRADLEY CONSTRUCTION COMPANY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BRADLEY CONSTRUCTION COMPANY INC. in 5204 SHERRIER PL, WASHINGTON, DC 20011 (NAICS 236115). OSHA activity number 338967979.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRADLEY CONSTRUCTION COMPANY INC.
- Site address
- 5204 SHERRIER PL
- City
- WASHINGTON
- State
- DC
- ZIP
- 20011
- Mailing
- 11515 MOUNTAIN VIEW ROAD, DAMASCUS, MD 20872
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 9
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.404 B01 II
- Issued
- May 13, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) On or about March 1, 2013; first floor; subcontracted employees were using portable electrical equipment, such as but not limited to circular saws, that were plugged into outlets either directly or by portable extension cords which were not equipped with a ground fault circuit interrupter. For the purposes of this inspection, the employer was determined to be the controlling and correcting employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy.
Recent events (2)
- — I (O) $800
- — Z (S) $1600
1926.405 B02
- Issued
- May 13, 2013
- Abate by
- Jun 7, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers: a) On or about March 1, 2013; first floor; subcontracted employees were using unguarded energized outlets either plugged in directly or by portable extension cords to power electrical equipment, such as but not limited to saws and portable lighting. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement. For the purposes of this inspection, the employer was determined to be the controlling and correcting employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy.
Recent events (2)
- — I (O) $800
- — Z (S) $1600
1926.501 B13
- Issued
- May 13, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) On or about March 1, 2013; roof area north, subcontracted employees were observed working on a 10 in 12 pitch roof of a two story residential home without a personal fall arrest system in place to prevent them from falling 30-35 feet to ground level. b) On or about March 1, 2013; throughout the second floor, subcontracted employees were also observed working around open working/walking surfaces within the residential construction that were not properly guarded by a guard rail system; exposing them to a 12 foot fall to the lower level. c) On or about March 1, 2013; throughout the site, subcontracted employees were working around wall openings that were not properly guarded to protect them from falling 15 feet to ground level. For the purposes of this inspection, the employer was determined to be the controlling and correcting employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B01
- Issued
- May 13, 2013
- Abate by
- Jun 7, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigged support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a) On or about March 1, 2013; second floor; subcontracted employees were using a step ladder that did not extended 3 feet above the landing to access the working platform to install the trusses. For the purposes of this inspection, the employer was determined to be the controlling and correcting employer of the jobsite. The employer is being cited under OSHA's Multi-Employer Workplace Policy. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
More inspections at Bradley Construction Company INC.