SHEFFIELD, AL ·
OSHA Inspection: 3-D, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of 3-D, LLC in 404 NORTH COLUMBIA AVENUE, SHEFFIELD, AL 35660 (NAICS 326199). OSHA activity number 338968035.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 3-D, LLC
- Site address
- 404 NORTH COLUMBIA AVENUE
- City
- SHEFFIELD
- State
- AL
- ZIP
- 35660
- Mailing
- P.O. BOX 638, SHEFFIELD, AL 35660
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 8
- Ownership type
- Private (A)
Citations
13 citations on file for this inspection.
1910.95 G01
- Issued
- May 8, 2013
- Abate by
- Sep 2, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
8110
General-duty citation text
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: (a) On or about March 20, 2013 - Manufacturing area, an employee operating a grinder was exposed to continuous noise at 104.2 % of the allowable 8-hour time-weighted average sound level of 90 dBA, or an equivalent sound level of approximately 90 dBA. The sampling was performed for 420 minutes during the day shift on 3/20/13. Zero exposure was assumed for the unsampled period of time of 60 minutes.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.95 K01
- Issued
- May 8, 2013
- Abate by
- Sep 2, 2013
- Penalty
- Initial $0 · Current $0
8110
General-duty citation text
29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k): (a) On or about March 20, 2013. Manufacturing area, an employee operating a grinder was exposed to continuous noise at 104.2% of the allowable 8-hour time-weighted average sound level of 90 dBA, or an equivalent sound level of approximately 90 dBA. The sampling was performed for 420 minutes during the day shift on 3/20/13. Zero exposure was assumed for the unsampled period of time of 60 minutes.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.157 C01
- Issued
- May 8, 2013
- Abate by
- May 8, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) On or about March 19, 2013 - Small warehouse, one portable fire extinguisher, ABC type, was blocked with pieces of wood making the equipment not readily accessible in the event of a fire.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.157 E02
- Issued
- May 8, 2013
- Abate by
- Jun 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: (a) On or about March 19, 2013 - Facility, portable fire extinguishers, ABC type, were not visually inspected every month.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.157 G01
- Issued
- May 8, 2013
- Abate by
- Sep 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: (a) On or about March 19, 2013 - Facility, employees who were expected to use portable fire extinguishers in the event of a fire had not been provided training in the use of the equipment.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.215 A02
- Issued
- May 8, 2013
- Abate by
- May 20, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: (a) On or about March 19, 2013 - Welex wire line, Black and Decker bench grinder, SN 6650, the left abrasive wheel was not provided with a guard to cover the spindle end, nut and flange projections.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.215 A04
- Issued
- May 8, 2013
- Abate by
- May 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch: (a) On or about March 19, 2013 - Welex wire line, Black and Decker bench grinder, SN 6650, the work rest was located at approximately 3/4 inch from the wheel.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.215 B09
- Issued
- May 8, 2013
- Abate by
- May 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: (a) On or about March 19, 2013 - Fence extruder area, Skil 3380 bench grinder, the abrasive wheel was not provided with an adjustable tongue guard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 G01
- Issued
- May 8, 2013
- Abate by
- May 20, 2013
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about March 19, 2013 - Fence line room, one electrical box that provides power to the chiller used in the extruder machine was blocked with a water tank preventing access to the box. (b) On or about March 20, 2013 - Welex extruder line, back of the room, electrical boxes that provided power to the extruder machines and the lights were obstructed by several containers with pellets.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1910.132 D02
- Issued
- May 8, 2013
- Abate by
- Jun 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: (a) On or about March 19, 2013 - Facility, no written certification to verify the hazard assessment had been performed.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 C02 I
- Issued
- May 8, 2013
- Abate by
- May 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (a) On or about March 19, 2013 - Facility, the employer did not provide the information contained in Appendix D of 29 CFR 1910.134 to employees who used 3M dust masks voluntarily.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 D01 II
- Issued
- May 8, 2013
- Abate by
- May 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification: (a) On or about March 19, 2013 - Facility, the employer provided 3M dust masks that were not certified by NIOSH.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 E01
- Issued
- May 8, 2013
- Abate by
- Sep 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On or about March 19, 2013 - Facility, a written hazard communication program had not been developed and implemented for employees exposed to chemicals such as polyethylene, carbon black (color pellet), aluminum hydroxide (white pellet), PVC resin (compound 49), and calcium carbonate (compound # 75).
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 326199)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338968035.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.