Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNCOAST ROOFERS SUPPLY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SUNCOAST ROOFERS SUPPLY in 10673 CROSS CREEK BLVD, TAMPA, FL 33677 (NAICS 444190). OSHA activity number 338968647.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Suncoast Roofers Supply — free Get an email when a new federal OSHA severe-injury report for Suncoast Roofers Supply is published. One employer, no account, unsubscribe in one click.
Site address
10673 CROSS CREEK BLVD
City
TAMPA
State
FL
ZIP
33677
Mailing
14212 N NEBRASKA AVE, TAMPA, FL 33613
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B04 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
May 20, 2013
Abate by
May 28, 2013
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers:  a) Site - 10673 Cross Creek Blvd. Tampa, Fl. 33647 Northeast Roof Area - Second Skylight Area  A 4'x4' section of plywood covering a skylight hole was removed allowing for a 20' foot fall  onto a pallet of drywall mortar bags on or about, 03/15/13.  OR IN THE ALTERNATE:  29 CFR 1926.502(d)(16)(iii) : The personal fall arrest system was not rigged that an employee can neither free fall more than 6 feet, nor contact any lower level:  a) Site - 10673 Cross Creek Blvd. Tampa, Fl. 33647  Northeast Roof Area -Second Skylight Area  The fall arrest system was not rigged as required and allowed for a 20' foot fall onto a pallet of drywall mortar bags upon stepping into an unguarded skylight hole, on or about, 03/15/13.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

1926.502 D21

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 20, 2013
Abate by
May 20, 2013
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:  a) Site - 10673 Cross Creek Blvd. Tampa, Fl. 33647  A lifeline used as part of a personal fall arrest system during the delivery of roof shingles was not removed from service despite exposed rope fibers, on or about, 03/15/13.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

View Suncoast Roofers Supply's full OSHA safety record →