Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DESIGN PLASTICS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DESIGN PLASTICS INC. in 3550 KEYSTONE DR, OMAHA, NE 68134 (NAICS 326199). OSHA activity number 338968910.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Design Plastics INC. — free Get an email when a new federal OSHA severe-injury report for Design Plastics INC. is published. One employer, no account, unsubscribe in one click.
Site address
3550 KEYSTONE DR
City
OMAHA
State
NE
ZIP
68134
Mailing
3550 KEYSTONE DR, OMAHA, NE 68134
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
48
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 9, 2013
Abate by
Sep 26, 2013
Penalty
Initial $2,678 · Current $1,875 Reduced
29 CFR 1910.147(c)(4)(ii):  The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to the items of this section:    3550 Keystone Dr., Omaha, NE 68134 (Site-Wide): The employer did not ensure that the lockout procedures used by employees to service equipment were adequately specific. The procedures had specific steps for shutting the equipment down and for starting the equipment up for production purposes, but did not have procedures for doing so for servicing equipment, including, but not limited to, the 500-ton Injection Molder (JSW-3).    Abatement certification and abatement documentation is required for this violation.  The abatement certification sheet is enclosed.
Recent events (2)
  • — I (S) $1874.6
  • — Z (S) $2678

1910.212 A01

Serious Gravity 5 2 instances 1 exposed
Issued
Aug 9, 2013
Penalty
Initial $1,821 · Current $1,275 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    3550 Keystone Dr., Omaha, NE 68134 (Maintenance Shop  North Wall, Engineering Shop): The employer did not ensure that adequate machine guarding was provided on machinery including, but not limited to the Buffalo drill press and the Gwang Ju Nam Seon lathe.
Recent events (2)
  • — I (S) $1274.7
  • — Z (S) $1821

1910.303 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 9, 2013
Penalty
Initial $2,276 · Current $1,593 Reduced
29 CFR 1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electrical equipment to permit ready and safe operation and maintenance of such equipment:    3550 Keystone Dr., Omaha, NE 68134 (Windscreen Area  South Wall): The employer did not ensure that sufficient access and working space was not provided and maintained about all electrical equipment to permit ready and safe operation and maintenance of such equipment. The area in front of a 240VAC electrical panel was used for storage.
Recent events (2)
  • — I (S) $1593.2
  • — Z (S) $2276

1910.305 A02 IX

Serious Gravity 5 2 instances 1 exposed
Issued
Aug 9, 2013
Penalty
Initial $1,821 · Current $1,275 Reduced
29 CFR 1910.305(a)(2)(ix): A lamp for general illumination was not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard:                                                                                                                            3550 Keystone Dr., Omaha, NE 68134 (Maintenance Shop - North Wall, Engineering Shop): The employer did not ensure that adequate lamp guards were provided on the lamps illuminating the Buffalo drill press and the Gwang Ju Nam Seon lathe.
Recent events (2)
  • — I (S) $1274.7
  • — Z (S) $1821

View Design Plastics INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338968910.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.