Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: DAVIS IRON WORKS, LTD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAVIS IRON WORKS, LTD in 224 N. HEWITT DR., HEWITT, TX 76643 (NAICS 423510). OSHA activity number 338969116.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Davis Iron Works, LTD for free Get an email when a new federal OSHA severe-injury report for Davis Iron Works, LTD is published. One employer, no account, unsubscribe in one click.
Site address
224 N. HEWITT DR.
City
HEWITT
State
TX
ZIP
76643
Mailing
224 N. HEWITT DR., HEWITT, TX 76643
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
54
Ownership type
Private (A)

6 citations on file for this inspection.

1910.23 D01

Serious Gravity 5 2 instances 5 exposed
Issued
May 9, 2013
Abate by
Jun 7, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.23(d)(1): The employer did not provide standard railings or guards on stairways having four or more risers.      On or about March 18, 2013, and times prior thereto, in the beam punch line area, the employer did not provide handrails and mid-rails to the stairs with 4 or more risers exposing employees to fall hazards.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.37 B02

Other-than-serious 2 instances 5 exposed
Issued
May 9, 2013
Abate by
Jun 7, 2013
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit".      On or about March 18, 2013, and times prior thereto, exit signs were not installed above the emergency exit doors exposing employees to fire hazards at the following locations:    a) in the warehouse, and    b) in the B-Fab shop.
Recent events (2)
  • · I (O) $0
  • · Z (S) $2100

1910.213 P01

Serious Gravity 5 2 instances 5 exposed
Issued
May 9, 2013
Abate by
Jun 7, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.213(p)(1): Feed rolls of self-feed sanding machine(s) were not protected with semicylindrical guard to prevent the hands of the operator from coming in contact with the in-running rolls.      On or about March 18, 2013, and times prior thereto, in the Structural Fab area, employees utilized two floor-mounted sanders that did not have guards, exposing employees to caught-by and struck-by hazards.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
May 9, 2013
Abate by
Jun 7, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel.        On or about March 18, 2013, and times prior thereto, in the machine shop area, the employer did not ensure the bench grinder had a tongue guard exposing employees to struck-by hazards.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
May 9, 2013
Abate by
Jun 7, 2013
Penalty
Initial $2,100 · Current $1,680 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.       On or about March 18, 2013, and times prior thereto, in the B-Fab shop area, employees using compressed air that was not reduced to less than 30 p.s.i. for cleaning purposes were exposed to eye and skin injuries.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2100

1910.305 G01 III

Serious Gravity 1 1 instance 1 exposed
Issued
May 9, 2013
Abate by
Jun 7, 2013
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph.      On or about March 18, 2013, and times prior thereto, in the maintenance shop area, the employer used a flexible cord as a substitute for a power cord to energize the cathodic protection junction box exposing employees to electrical hazards.
Recent events (2)
  • · I (S) $1260
  • · Z (S) $2100

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 338969116.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.