Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RELIANCE BUILDING SYSTEMS, L.L.C.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of RELIANCE BUILDING SYSTEMS, L.L.C. in 9340 N SAM HOUSTON PKWY E, HUMBLE, TX 77396 (NAICS 236220). OSHA activity number 338970734.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reliance Building Systems, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Reliance Building Systems, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
9340 N SAM HOUSTON PKWY E
City
HUMBLE
State
TX
ZIP
77396
Mailing
4340 E. INDIAN SCHOOL SCHOOL RD. STE 21-484, PHOENIX, AZ 85016
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
20
Ownership type
A

3 citations on file for this inspection.

1926.502 D16 III

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 19, 2013
Abate by
May 8, 2013
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  The employer does not ensure personal fall arrest systems are rigged so that the employee could not free fall 6 feet nor contact a lower level. This violation was observed on or about March 21, 2013, on the north side of a newly built commercial building where an employee was exposed to an 8 foot fall hazard while sitting on a metal beam with a 6 foot lanyard attached to his d-ring.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that personal fall arrest systems are rigged such that an employee could not free fall more than 6 feet nor contact a lower level.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.403 B01

Other-than-serious 1 instance 20 exposed
Issued
Apr 19, 2013
Abate by
May 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:  The employer does not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious harm to employees. This violation was observed on or about March 21, 2013, on the south side of the building where employees were using a Bosch Worm Drive Saw without a ground pin being installed on the electrical cord. The employer did not remove the equipment from service.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Apr 19, 2013
Abate by
May 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:   The employer does not ensure paths to ground from circuits, equipment , or enclosures are permanent and continuous. This violation was observed on or about March 12, 2013, on the south side of the building where employees were using a Bosch Worm Drive Saw without a ground pin being installed on the electrical cord. The cord was plugged into a GFCI outlet.   Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that paths to ground from circuits, equipment, or enclosures are permanent and continuous.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338970734.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.