OSHA Inspection: LAFAYETTE INDUSTRIES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LAFAYETTE INDUSTRIES in 179 GAYWOOD, MANCHESTER, MO 63021 (NAICS 624310). OSHA activity number 338971740.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lafayette Industries for free Get an email when a new federal OSHA severe-injury report for Lafayette Industries is published. One employer, no account, unsubscribe in one click.
Site address
179 GAYWOOD
City
MANCHESTER
State
MO
ZIP
63021
Mailing
179 GAYWOOD, MANCHESTER, MO 63021
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
624310
Employees
260
Ownership type
Private (A)

3 citations on file for this inspection.

1910.303 B02

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 4, 2013
Abate by
May 21, 2013
Penalty
Initial $2,550 · Current $1,275 Reduced
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  1) At the TEXWRAP machine (Model 2219, SN #D1164), the drop cord from the ceiling junction box was plugged into an extension cord which ran along the drop ceiling into another extension cord servicing both the electrical box for the TEXWRAP machine and the in feed conveyor for the TEXWRAP machine.  Extension cords were not used according to the manufacturer's instructions.    2) At the portable conveyor dedicated to the Shrink Wrap machine work area, the drop cord was plugged into an extension cord, pinched between the conveyor belt and table, and traveled across the floor by employees feet into another extension cord which serviced the portable conveyor.   Extension cords were not used according to the manufacturer's instructions.      IN THE ALTERNATIVE:    29 CFR 1910.305(g)(1)(iv)(A)  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  1) At the TEXWRAP machine (Model 2219, SN #D1164), the drop cord from the ceiling junction box was plugged into an extension cord which ran along the drop ceiling into another extension cord servicing both the electrical box for the TEXWRAP machine and the in feed conveyor for the TEXWRAP machine.  Temporary wiring was used in lieu of fixed wiring.    2) At the portable conveyor dedicated to the Shrink Wrap machine work area, the drop cord was plugged into an extension cord, pinched between the conveyor belt and table, and traveled across the floor by employees feet into another extension cord which serviced the portable conveyor.   Temporary wiring was used in lieu of fixed wiring.
Recent events (2)
  • · I (S) $1275
  • · Z (S) $2550

1910.305 A02 X

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(x)  Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:    1) At the portable conveyor dedicated to the Shrink Wrap machine work area, the drop cord was plugged into an extension cord, which was pinched between the conveyor belt and table, and traveled across the floor by employees feet into another extension cord that serviced the portable conveyor.   The extension cord was not protected from the pinch point.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 4, 2013
Abate by
May 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii)  Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  At the CONFLEX in feed conveyor (SN # CJ08140-01) the drop cord was plugged into an extension cord which serviced the in feed conveyor and the cord and plug lacked strain relief.