PEABODY, MA —
OSHA Inspection: GC FODERA CONTRACTING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GC FODERA CONTRACTING, LLC in 119 FOSTER STREET, BLDG 1, PEABODY, MA 01960 (NAICS 238140). OSHA activity number 338974439.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GC FODERA CONTRACTING, LLC
- Site address
- 119 FOSTER STREET, BLDG 1
- City
- PEABODY
- State
- MA
- ZIP
- 01960
- Mailing
- 1820 TURNPIKE STREET, NORTH ANDOVER, MA 01845
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 C02 I
- Issued
- May 6, 2013
- Abate by
- May 6, 2013
- Penalty
- Initial $2,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement. (a) Location - 119 Foster Street Building 1, Peabody, MA: On or about 3/25/2013, employees were working from a tubular welded scaffold that was supported in two sections at the base by concrete cinder blocks.
Recent events (2)
- — I (S) $1000
- — Z (S) $2200
1926.451 F06
- Issued
- May 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines. (a) Location - 119 Foster Street Building 1, Peabody, MA: On or about 3/25/2013, employees were working from a tubular welded scaffold that had energized power lines going through the sections of scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 C02
- Issued
- May 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. (a) Location - 119 Foster Street Building 1, Peabody, MA: On or about 3/25/2013, employees were working from a tubular welded scaffold that was missing a cross brace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G04 I
- Issued
- May 6, 2013
- Abate by
- May 6, 2013
- Penalty
- Initial $2,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. (a) Location - 119 Foster Street Building 1, Peabody, MA: On or about 3/25/2013, employees were working from a tubular welded scaffold that did not have top and end guardrails installed to protect employees from falling.
Recent events (2)
- — I (S) $1000
- — Z (S) $2200
More inspections at GC Fodera Contracting, LLC
View GC Fodera Contracting, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338974439.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.