OSHA Inspection: DEAN DAIRY HOLDINGS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEAN DAIRY HOLDINGS LLC in 315 N BUMBY AVE, ORLANDO, FL 32803 (NAICS 311511). OSHA activity number 338974538.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dean Dairy Holdings LLC for free Get an email when a new federal OSHA severe-injury report for Dean Dairy Holdings LLC is published. One employer, no account, unsubscribe in one click.
Site address
315 N BUMBY AVE
City
ORLANDO
State
FL
ZIP
32803
Mailing
1126 KILBURN AVE., ROCKFORD, IL 61110
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311511
Employees
150
Ownership type
Private (A)

11 citations on file for this inspection.

1910.23 C03

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 16, 2013
Penalty
Initial $2,869 · Current $1,721 Reduced
29 CFR 1910.23(c)(3): Standard railing(s) and toeboard(s) were not provided on open sided floor(s), walkway(s), or runway(s), adjacent to or above dangerous equipment:  a. Case dock compactor area, employees were exposed to the hazard of falling into the compactor during its operating cycle, in that, the top railing on the platform used to feed cardboard into the compactor was broken off.
Recent events (2)
  • · I (S) $1721.4
  • · Z (S) $2869

1910.23 D01

Serious Gravity 1 3 instances 7 exposed
Issued
Sep 16, 2013
Abate by
Sep 30, 2013
Penalty
Initial $2,025 · Current $1,215 Reduced
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section:   a. At the machine room exit, a four step stairway outside the building was not provided with a handrail system.   b. At the roof area, a 23 step stairway leading from the maintenance roof top to the roof over the boilers was not provided with a midrail. The stairway had only a handrail installed at 29 inches from the nosing of the risers.    c. Glycol Chiller motor area,  a 6 step stairway leading to the motors was not provided with handrails.
Recent events (2)
  • · I (S) $1215
  • · Z (S) $2025

1910.119 E03 I

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 16, 2013
Abate by
Dec 17, 2013
Penalty
Initial $3,375 · Current $2,025 Reduced
29 CFR 1910.119(e)(3)(i): The Process Hazard Analysis did not address the hazards of the process:   a. The PHAs did not address the hazards of the process to include the following:    1.The ventilation system for the machine room was not designed to exhaust ammonia vapors out of the room and into a safe area.  The three wall mounted fans on the north wall were exhausting the vapors into a space between the buildings permitting vapors to travel into areas of the plant such as but not limited to the boiler room.   2. The machine room was not sealed properly in that; the north wall of the machine room did not extend to the ceiling.  The wall terminated approximately two to three feet below the room ceiling.  Additionally, openings where piping passed through the walls the opening(s) were not sealed.  In the event of a release refrigerant could escape into unventilated areas of the facility.
Recent events (2)
  • · I (S) $2025
  • · Z (S) $3375

1910.119 J02

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 16, 2013
Penalty
Initial $2,869 · Current $1,721 Reduced
29 CFR 1910.119(j)(2): The employer did not establish or implement written procedures to maintain the on-going integrity of process equipment:    a. At the site, the inspection, testing and preventive maintenance program implemented did not include vibration testing and oil testing to assure the ongoing integrity of equipment such as but not limited to compressors and other equipment with rotating parts.
Recent events (2)
  • · I (S) $1721.4
  • · Z (S) $2869

1910.212 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 16, 2013
Abate by
Sep 26, 2013
Penalty
Initial $3,375 · Current $2,025 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   a. Maintenance shop, a MSC horizontal band saw serial number 313576 and model number 400516690 did not have a guard over the non-cutting portion of the blade.
Recent events (2)
  • · I (S) $2025
  • · Z (S) $3375

1910.212 A03 II

Serious Gravity 5 2 instances 10 exposed
Issued
Sep 16, 2013
Abate by
Oct 3, 2013
Penalty
Initial $3,375 · Current $2,025 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):      a. Maintenance room, employees were exposed to the point of operation of an ENCO milling machine, in that, a guard was not provided around the milling drill bit.     b. Maintenance room, employees were exposed to the point of operation of a Guard Lite Dual Protection chop saw serial number 137012, in that, the lower portion of the rotating blade was not provide with a guard.
Recent events (2)
  • · I (S) $2025
  • · Z (S) $3375

1910.303 F01

Serious Gravity 1 2 instances 7 exposed
Issued
Sep 16, 2013
Abate by
Sep 20, 2013
Penalty
Initial $2,025 · Current $1,215 Reduced
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:     a. Bottle area, employees were exposed to electrical hazards, in that, panel LPA 208/120V had 6 breakers without a label indicating their purpose.   b. Machine room, employees were exposed to electrical hazards, in that, breaker panel CP 3/4/7 had three breakers without a label indicating their purpose.
Recent events (2)
  • · I (S) $1215
  • · Z (S) $2025

1910.303 G01 I A

Serious Gravity 1 1 instance 7 exposed
Issued
Sep 16, 2013
Abate by
Oct 3, 2013
Penalty
Initial $2,025 · Current $1,215 Reduced
29 CFR 1910.303(g)(1)(i)(A):  The dimensions of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while energized was less than indicated in Table S1:   a. At the glycol cooling pumps, employees were exposed to electrical hazards, in that, the disconnects and control panel for the cooling pumps were installed on the wall behind the pumps and were not readily accessible.
Recent events (2)
  • · I (S) $1215
  • · Z (S) $2025

1910.304 F01 IV

Serious Gravity 1 2 instances 7 exposed
Issued
Sep 16, 2013
Penalty
Initial $1,721 · Current $1,033 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices were not readily accessible to each employee or authorized building management personnel:  a. At the machine room, the working space in front of the breaker panel was used for storage. Tool boxes, poly drums containing a cleaner sanitizer and other equipment were stored right in front of power panel CP 3/4/7.    b. Boiler room east wall, the working space in front of 6 electrical panels was used for storage, in that, a poly drum and a boiler feed tank supplying a solution for alkaline control were stored in front of the panels.
Recent events (2)
  • · I (S) $1032.6
  • · Z (S) $1721

1910.24 G

Other-than-serious 1 instance 7 exposed
Issued
Sep 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.24(g): Stairway platforms were not at least the width of the stairway and a minimum of 30 inches in length measured in the direction of travel:    a. Refrigeration engine room, a two door exit at the machine room leading to the exterior of a building opened directly on a 4 step stairway without a platform.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 G01 IV A

Other-than-serious 2 instances 7 exposed
Issued
Sep 16, 2013
Abate by
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a. Glycol cooling pump area, a red and a black extension cords were used to provide power to the air pumps.   b. Filler number 6 small bottle area, employees were exposed to electrical hazards, in that, two black extension cords were used to provide power to the sanitizer pumps.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Dean Dairy Holdings LLC's full OSHA safety record →