Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: K.J. CUSTOM CARPENTRY LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of K.J. CUSTOM CARPENTRY LLC in 205 COOLIDGE AVE., BARRINGTON, IL 60010 (NAICS 238130). OSHA activity number 338975089.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch K.J. Custom Carpentry LLC — free Get an email when a new federal OSHA severe-injury report for K.J. Custom Carpentry LLC is published. One employer, no account, unsubscribe in one click.
Site address
205 COOLIDGE AVE.
City
BARRINGTON
State
IL
ZIP
60010
Mailing
27625 N. OAK, ISLAND LAKE, IL 60042
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

6 citations on file for this inspection.

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 5, 2013
Abate by
Jun 11, 2013
Penalty
Initial $2,800 · Current $1,120 Reduced
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet (0.6 m) above or below a point of access:     a) Employees were not provided with safe access to scaffolding from which they were required to work at an elevation of approximately 22 feet.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $2800

1926.451 G01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 5, 2013
Abate by
Jun 11, 2013
Penalty
Initial $2,800 · Current $1,120 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:     a) Employees were exposed to the hazard of falling approximately 22 feet while working from ladder jack scaffolding without the benefit of fall protection.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 5, 2013
Abate by
Jun 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):    a) Employees were exposed to the hazard of falling while working from a pitched roof without the use of fall protection.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 5, 2013
Abate by
Jun 11, 2013
Penalty
Initial $2,800 · Current $1,120 Reduced
29 CFR 1926.452(k)(1): Ladder jack scaffold platforms exceeded a height of 20 feet (6.1 m):     a) Employees were exposed to the hazard of falling approximately 22 feet during the performance of work from a ladder jack scaffold that exceeded the 20 foot maximum permissible height for ladder jack scaffolding.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $2800

1926.1053 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 5, 2013
Abate by
Jun 5, 2013
Penalty
Initial $1,200 · Current $480 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:      a) A stepladder was used without its metal spreaders or locking devices in the open position.    No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $480
  • — Z (S) $1200

1926.503 B01

Other-than-serious 2 instances 1 exposed
Issued
Jun 5, 2013
Abate by
Jul 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record:      a) The employer did not prepare written certification records related to employee fall protection training.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View K.J. Custom Carpentry LLC's full OSHA safety record →