NEW MILFORD, PA —
OSHA Inspection: NORTHEAST ENERGY MANAGEMENT, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORTHEAST ENERGY MANAGEMENT, INC in 944 ALEXANDER RD RIG #11, NEW MILFORD, PA 18834 (NAICS 213112). OSHA activity number 338976111.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTHEAST ENERGY MANAGEMENT, INC
- Site address
- 944 ALEXANDER RD RIG #11
- City
- NEW MILFORD
- State
- PA
- ZIP
- 18834
- Mailing
- 2018 S 6TH ST, INDIANA, PA 15701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Apr 3, 2013
- Abate by
- Apr 15, 2013
- Penalty
- Initial $6,930 · Current $5,197 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder: a) Rig #11, Susquehanna County: The left side fuel tank access platform on the Schramm TXD 200 air drilling rig was not equipped with guardrails exposing workers to a fall hazard of approximately 4 feet, 10 inches, on or about March 26, 2013. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5197
- — Z (S) $6930
1910.23 E01
- Issued
- Apr 3, 2013
- Abate by
- Apr 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(1): Standard railings did not consist of top rails, intermediate rails, and posts: a) Rig #11, Susquehanna County: The V door opening on the rig floor was not equipped with a top rail exposing workers to a fall hazard of approximately 8 feet, on or about March 26, 2013. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Apr 3, 2013
- Penalty
- Initial $2,970 · Current $2,227 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch: a) Rig #11, Susquehanna County: A Jet model JBG-8A bench grinder was not equipped with a properly adjusted tongue guard exposing workers to the hazard of being struck by flying debris, on or about March 26, 2013. CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
- — I (S) $2227
- — Z (S) $2970
1910.305 G01 IV A
- Issued
- Apr 3, 2013
- Abate by
- Apr 15, 2013
- Penalty
- Initial $4,950 · Current $3,712 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: a) Rig #11, Susquehanna County: An improperly installed extension cord that was run between the doghouse and the diesel fuel storage tank exposed workers to an electric shock hazard, on or about March 26, 2013. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $3712
- — Z (S) $4950
1910.305 G01 IV B
- Issued
- Apr 3, 2013
- Abate by
- Apr 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were improperly used when run through holes in walls, ceilings, or floors: a) Rig #11, Susquehanna County: An extension cord used to power a fuel transfer pump was run through a hole in the dog house floor exposing the cord to damage and workers to an electric shock hazard, on or about March 26, 2013. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Northeast Energy Management, INC
View Northeast Energy Management, INC's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338976111.