Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTHEAST ENERGY MANAGEMENT, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NORTHEAST ENERGY MANAGEMENT, INC in 944 ALEXANDER RD RIG #11, NEW MILFORD, PA 18834 (NAICS 213112). OSHA activity number 338976111.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northeast Energy Management, INC — free Get an email when a new federal OSHA severe-injury report for Northeast Energy Management, INC is published. One employer, no account, unsubscribe in one click.
Site address
944 ALEXANDER RD RIG #11
City
NEW MILFORD
State
PA
ZIP
18834
Mailing
2018 S 6TH ST, INDIANA, PA 15701
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
10
Ownership type
A

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 3, 2013
Abate by
Apr 15, 2013
Penalty
Initial $6,930 · Current $5,197 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder:    a) Rig #11, Susquehanna County: The left side fuel tank access platform on the Schramm TXD 200 air drilling rig was not equipped with guardrails exposing workers to a fall hazard of approximately 4 feet, 10 inches, on or about March 26, 2013.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $5197
  • — Z (S) $6930

1910.23 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 3, 2013
Abate by
Apr 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(1): Standard railings did not consist of top rails, intermediate rails, and posts:  a) Rig #11, Susquehanna County: The V door opening on the rig floor was not equipped with a top rail exposing workers to a fall hazard of approximately 8 feet, on or about March 26, 2013.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 3, 2013
Penalty
Initial $2,970 · Current $2,227 Reduced
29 CFR 1910.215(b)(9): The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch:    a) Rig #11, Susquehanna County: A Jet model JBG-8A bench grinder was not equipped with a properly adjusted tongue guard exposing workers to the hazard of being struck by flying debris, on or about March 26, 2013.     CORRECTED DURING INSPECTION   CERTIFICATION NOT REQUIRED
Recent events (2)
  • — I (S) $2227
  • — Z (S) $2970

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Apr 3, 2013
Abate by
Apr 15, 2013
Penalty
Initial $4,950 · Current $3,712 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure:    a) Rig #11, Susquehanna County: An improperly installed extension cord that was run between the doghouse and the diesel fuel storage tank exposed workers to an electric shock hazard, on or about March 26, 2013.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $3712
  • — Z (S) $4950

1910.305 G01 IV B

Other-than-serious 1 instance 2 exposed
Issued
Apr 3, 2013
Abate by
Apr 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were improperly used when run through holes in walls, ceilings, or floors:    a) Rig #11, Susquehanna County: An extension cord used to power a fuel transfer pump was run through a hole in the dog house floor exposing the cord to damage and workers to an electric shock hazard, on or about March 26, 2013.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Northeast Energy Management, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338976111.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.