COLUMBIA, SC —
OSHA Inspection: NASH, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NASH, INC. in 11902-A GOLDEN ARROW ROAD, COLUMBIA, SC 29207 (NAICS 238220). OSHA activity number 338976707.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NASH, INC.
- Site address
- 11902-A GOLDEN ARROW ROAD
- City
- COLUMBIA
- State
- SC
- ZIP
- 29207
- Mailing
- PO BOX 98, COLEMAN, FL 33521
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.350 A10
- Issued
- Apr 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour. a) West end of the site, outside of the south side of the Office Trailer: An oxygen compressed gas cylinder was stored within 16 feet of two acetylene compressed gas cylinders.
Recent events (1)
- — Z (O) $0
1926.405 A02 II E
- Issued
- Apr 12, 2013
- Abate by
- Apr 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage. West end of the site: Four sets of florescent lights used in the job trailer were 6 feet, 9 inches from the floor and none were protected from breakage by covers.
Recent events (1)
- — Z (O) $0
More inspections at Nash, INC.
View Nash, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in SC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338976707.